Lantronix SLC 32 Lantronix SLC - User Guide - Page 45
General CLI Commands, Table 5-1, SCS and SLC Commands
View all Lantronix SLC 32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
5: Web and Command Line Interfaces To clear an IP address, type 0.0.0.0, or to clear a non-IP address value, type CLEAR. When the number of lines displayed by a command exceeds the size of the window (the default is 25), the command output is halted until the user is ready to continue. To display the next line, press Enter, and to display the page, press the space bar. You can override the number of lines (or disable the feature altogether) with the set cli command. General CLI Commands The following commands relate to the CLI itself. To configure the current command line session: set cli scscommands Allows you to use SCS-compatible commands as shortcuts for executing commands. Note: Settings are retained between CLI sessions for local and remote users. SCS Commands info version reboot poweroff listdev direct listen clear telnet ssh Table 5-1 SCS and SLC Commands SLC Commands show sysstatus admin version admin reboot admin shutdown show deviceport names connect direct deviceport connect listen deviceport set locallog clear connect direct telnet connect direct ssh To start a menu if a menu is associated with the current user and was not displayed at login: set cli menu start To set the number of lines displayed by a command: set cli terminallines Sets the number of lines in the terminal emulation screen for paging through text one screen at a time, if the SLC console manager cannot detect the size of the terminal automatically. To show current CLI settings: show cli SLC™ Console Manager User Guide 45