Lantronix SLC 32 Lantronix SLC - User Guide - Page 155

User Attributes and Permissions, from LDAP Schema on Local/Remote Users Commands

Page 155 highlights

12: User Authentication Bind Password and Retype Password Bind with Login Use LDAP Schema Active Directory Support Encrypt Messages Custom Menu Escape Sequence Break Sequence Enable for Dialback Dial-back Number Data Ports Listen Port Clear Port Buffers Enter the password for the user configured in Bind Name for a non-anonymous bind. This entry is optional. Acceptable characters are a-z, A-Z, and 0-9. The maximum length is 127 characters. Select to bind with the login and password that a user is authenticating with. This requires that the Bind Name contain the $login token, which will be replaced with the current login. For example, if the Bind Name is uid=$login,ou=People,dc=lantronix,dc=com, and user roberts logs into the SLC console manager, LDAP will bind with uid=roberts,ou=People,dc=lantronix,dc=com and the password entered by roberts. Click the check box to obtain remote user attributes (group/permissions and port access) from an Active Directory server scheme via the user attribute secure lantronixSLCPerms. Disabled by default. See User Attributes and Permissions from LDAP Schema on page 157. Click to enable. Active Directory is a directory service from Microsoft that is a part of Windows 2000 and later versions of Windows. It is LDAP- and Kerberoscompliant. Disabled by default. Select to encrypt messages between the SLC device and the LDAP server. Disabled by default. Assign a default customer menu to LDAP users, if custom menus have been created (see Local/Remote Users Commands on page 148). Enter a single character or a two-character sequence that causes the SLC console manager to leave direct (interactive) mode. (To leave listen mode, press any key.) A suggested value is Esc+A (escape key, then uppercase "A" performed quickly but not simultaneously). You would specify this value as \x1bA, which is hexadecimal (\x) character 27 (1B) followed by an A. This setting allows the user to terminate the connect direct command on the command line interface when the endpoint of the command is deviceport, tcp, or udp. Enter a series of 1-10 characters that users can enter on the command line interface to send a break signal to the external device. A suggested value is Esc+B (escape key, then uppercase "B" performed quickly but not simultaneously). You would specify this value as \x1bB, which is hexadecimal (\x) character 27 (1B) followed by a B. Select to grant a user dial-back access. Users with dial-back access can dial into the SLC device and enter their login and password. Once the SLC console manager authenticates them, the modem hangs up and dials them back. Disabled by default. Enter the device port that the modem dials to reach a user phone number. The user is dialed back on a fixed number or on a number that is associated with the user login (specified here). Enter the ports that users can monitor and interact with using the connect direct command. U and L denote the PC Card upper and lower slots. U1 denotes the USB port. Enter the ports that users can monitor using the connect listen command. Enter the ports that users can clear the port buffer by using the set log clear command. SLC™ Console Manager User Guide 155

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299

12: User Authentication
SLC™ Console Manager User Guide
155
Bind Password
and Retype
Password
Enter the password for the user configured in Bind Name for a non-anonymous
bind. This entry is optional. Acceptable characters are
a-z
,
A-Z,
and
0-9
. The
maximum length is 127 characters.
Bind with Login
Select to bind with the login and password that a user is authenticating with. This
requires that the Bind Name contain the
$login
token, which will be replaced with
the current login. For example, if the Bind Name is
uid=$login,ou=People,dc=lantronix,dc=com
, and user
roberts
logs into the
SLC console manager, LDAP will bind with
uid=roberts,ou=People,dc=lantronix,dc=com
and the password entered by
roberts.
Use LDAP Schema
Click the check box to obtain remote user attributes (group/permissions and port
access) from an Active Directory server scheme via the user attribute secure
lantronixSLCPerms. Disabled by default. See
User Attributes and Permissions
from LDAP Schema on page 157
.
Active Directory
Support
Click to enable. Active Directory is a directory service from Microsoft that is a part
of Windows 2000 and later versions of Windows. It is LDAP- and Kerberos-
compliant. Disabled by default.
Encrypt Messages
Select to encrypt messages between the SLC device and the LDAP server.
Disabled by default.
Custom Menu
Assign a default customer menu to LDAP users, if custom menus have been
created (see
Local/Remote Users Commands on page 148
).
Escape Sequence
Enter a single character or a two-character sequence that causes the SLC console
manager to leave direct (interactive) mode. (To leave listen mode, press any key.)
A suggested value is
Esc+A
(escape key, then uppercase “A” performed quickly
but not simultaneously). You would specify this value as
\x1bA
, which is
hexadecimal
(\x)
character 27
(
1B
) followed by an
A
.
This setting allows the user to terminate the
connect direct
command on the
command line interface when the endpoint of the command is
deviceport
,
tcp
,
or
udp
.
Break Sequence
Enter a series of 1-10 characters that users can enter on the command line
interface to send a break signal to the external device. A suggested value is
Esc+B
(escape key, then uppercase “B” performed quickly but not
simultaneously). You would specify this value as
\x1bB
,
which is hexadecimal
(\x)
character 27
(
1B
) followed by a
B
.
Enable for Dial-
back
Select to grant a user dial-back access. Users with dial-back access can dial into
the SLC device and enter their login and password. Once the SLC console
manager authenticates them, the modem hangs up and dials them back. Disabled
by default.
Dial-back Number
Enter the device port that the modem dials to reach a user phone number. The
user is dialed back on a fixed number or on a number that is associated with the
user login (specified here).
Data Ports
Enter the ports that users can monitor and interact with using the
connect
direct
command.
U
and
L
denote the PC Card upper and lower slots.
U1
denotes the USB port.
Listen Port
Enter the ports that users can monitor using the
connect listen
command.
Clear Port Buffers
Enter the ports that users can clear the port buffer by using the
set log clear
command.