Lenovo NetVista Hardware Maintenence Manual for Netvista 6838 and 6848 systems - Page 58
Diagnostic Error Code, FRU/Action
View all Lenovo NetVista manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
Diagnostic Error Code FRU/Action 000-024-XXX BIOS Addressing test failure 1. Flash the system 2. System board 000-025-XXX BIOS Checksum Value error 1. Flash the system 2. Boot block 3. System board 000-026-XXX FLASH data error 1. Flash the system 2. Boot block 3. System board 000-027-XXX BIOS Configuration/Setup error 1. Run Setup 2. Flash the system 3. Boot block 4. System board 000-034-XXX BIOS Buffer Allocation failure 1. Reboot the system 2. Flash the system 3. Run memory test 4. System board 000-035-XXX BIOS Reset Condition detected 1. Flash the system 2. System board 000-036-XXX BIOS Register error 1. Flash the system 2. Boot block 3. System board 000-038-XXX BIOS Extension failure 1. Flash the system 2. Adapter card 3. System board 000-039-XXX BIOS DMI data error 1. Flash the system 2. System board 000-195-XXX BIOS Test aborted by user 1. Information 2. Re-start the test, if necessary 000-196-XXX BIOS test halt, error threshold 1. Press F3 to review the log file exceeded 2. Re-start the test to reset the log file 000-197-XXX BIOS test warning 1. Make sure the component that is called out is connected and/or enabled 2. Re-run test 3. Component that is called out in warning statement 4. Component under test 000-198-XXX BIOS test aborted 1. If a component is called out, make sure it is connected and/or enabled 2. Flash the system and re-test 3. Go to the ″Undetermined problems″ section 50 IBM NetVista Type 6838, 6848: Hardware Maintenance Manual