Lenovo NetVista Hardware Maintenence Manual for Netvista 6838 and 6848 systems - Page 65

XX-XXX 014-3XX-XXX

Page 65 highlights

Diagnostic Error Code 014-199-XXX Parallel port test failed, cause unknown 014-2XX-XXX 014-3XX-XXX Parallel port failure 015-000-XXX USB port Interface Test Passed 015-001-XXX USB port Presence 015-002-XXX USB port Timeout 015-015-XXX USB port External Loopback failure 015-027-XXX USB port Configuration/Setup error 015-032-XXX USB port Device Controller failure 015-034-XXX USB port buffer allocation failure 015-035-XXX USB port Reset condition detected 015-036-XXX USB port Register error 015-040-XXX USB port IRQ failure 015-195-XXX USB port Test aborted by user 015-196-XXX USB port test halt, error threshold exceeded 015-197-XXX USB port test warning 015-198-XXX USB port test aborted FRU/Action 1. Go to the ″Undetermined problems″ section 2. Flash the system and re-test 3. Replace component under function test 1. External parallel device 2. System board 1. No action 1. Remove USB device(s) and re-test 2. System board 1. Remove USB device(s) and re-test 2. System board 1. Remove USB device(s) and re-test 2. System board 1. Flash the system 2. System board 1. System board 1. Reboot the system 2. Flash the system 3. Run memory test 4. System board 1. Remove USB device(s) and re-test 2. System board 1. System board 1. Run setup and check for conflicts 2. Flash the system 3. System board 1. Information 2. Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file 1. Make sure the component that is called out is connected and/or enabled 2. Re-run test 3. Component that is called out in warning statement 4. Component under test 1. If a component is called out, make sure it is connected and/or enabled 2. Flash the system and re-test 3. Go to the ″Undetermined problems″ section Chapter 7. Symptom-to-FRU index 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

Diagnostic Error Code
FRU/Action
014-199-XXX
Parallel port test failed, cause
unknown
1.
Go to the
Undetermined problems
section
2.
Flash the system and re-test
3.
Replace component under function test
014-2XX-XXX 014-3XX-XXX
Parallel port
failure
1.
External parallel device
2.
System board
015-000-XXX
USB port Interface Test Passed
1.
No action
015-001-XXX
USB port Presence
1.
Remove USB device(s) and re-test
2.
System board
015-002-XXX
USB port Timeout
1.
Remove USB device(s) and re-test
2.
System board
015-015-XXX
USB port External Loopback
failure
1.
Remove USB device(s) and re-test
2.
System board
015-027-XXX
USB port Configuration/Setup
error
1.
Flash the system
2.
System board
015-032-XXX
USB port Device Controller
failure
1.
System board
015-034-XXX
USB port buffer allocation
failure
1.
Reboot the system
2.
Flash the system
3.
Run memory test
4.
System board
015-035-XXX
USB port Reset condition
detected
1.
Remove USB device(s) and re-test
2.
System board
015-036-XXX
USB port Register error
1.
System board
015-040-XXX
USB port IRQ failure
1.
Run setup and check for conflicts
2.
Flash the system
3.
System board
015-195-XXX
USB port Test aborted by user
1.
Information
2.
Re-start the test, if necessary
015-196-XXX
USB port test halt, error
threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
015-197-XXX
USB port test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
015-198-XXX
USB port test aborted
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
Undetermined problems
section
Chapter 7. Symptom-to-FRU index
57