Lenovo NetVista Hardware Maintenence Manual for Netvista 6838 and 6848 systems - Page 73
Assure Asset Security Enabled, Diskette Drive Cable
View all Lenovo NetVista manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
Diagnostic Error Code FRU/Action 175-197-XXX Thermal Sensor(s) test warning 1. Make sure the component that is called out is connected and/or enabled 2. Re-run test 3. Component that is called out in warning statement 4. Component under test 175-198-XXX Thermal Sensor(s) test aborted 1. If a component is called out, make sure it is connected and/or enabled 2. Flash the system and re-test 3. Go to ″Undetermined problems″ section 175-199-XXX Thermal Sensor(s) test failed, cause unknown 1. Go to the ″Undetermined problems″ section 2. Flash the system and re-test 3. Replace component under function test 175-250-XXX 175-251-XXX Thermal Sensor(s) limit error 1. Check fans 2. Check Power supply 3. Microprocessor 4. System board 185-000-XXX Asset Security Test Passed 1. No action 185-XXX-XXX Asset Security failure 1. Flash system 2. System board 185-278-XXX Asset Security Chassis Intrusion 1. Assure Asset Security Enabled 2. C2 Cover Switch 3. System board 201-000-XXX System Memory Test Passed 1. No action 201-XXX-XXX System Memory error 1. Replace the memory module called out by the test 2. System board 202-000-XXX System Cache Test Passed 1. No action 202-XXX-XXX System Cache error 1. Cache, if removable 2. System board 3. Microprocessor 206-000-XXX Diskette Drive Test Passed 1. No action 206-XXX-XXX Diskette Drive error 1. Diskette Drive Cable 2. Check power supply voltages 3. Diskette drive 4. System board 215-000-XXX CD-ROM Drive Test Passed 1. No action 215-XXX-XXX CD-ROM Drive error 1. CD-ROM Drive Cable 2. Check power supply voltages 3. CD-ROM drive 4. System board Chapter 7. Symptom-to-FRU index 65