Yamaha MU100R MU100R Owners Manual - Page 135

Damping, Absorption

Page 135 highlights

Multi Edit Mode Harmonic Enhancer Control Depth (HrmCtrlDpt) Settings: -64 - +63 Damping Control Depth (DmpCtrlDpt) Settings: -64 - +63 Sets the amount of variation produced by the controller assigned to the harmonic enhancer. The higher the value, the greater the variation. Positive values cause an increase in harmonic enhancer depth in response to higher controller values (e.g., increased breath pressure or higher modulation wheel position), while negative values cause a decrease in harmonic enhancer depth in response to higher controller values. Damping Damping Control Change Number (Dmp CC No.) Settings: off, 01 - 31, off, 33 - 95, AT, VEL, PB Sets the amount of variation produced by the controller assigned to damping. The higher the value, the greater the variation. Positive values cause a decrease in damping in response to higher controller values (e.g., increased breath pressure or higher modulation wheel position), while negative values cause an increase in damping in response to higher controller values. Absorption Apsorption Control Change Number (Abs CC No.) Settings: off, 01 - 31, off, 33 - 95, AT, VEL, PB "Damping" simulates the effect of damping due to losses within the body of a wind instrument or in a string due to air friction. This affects both pitch and timbre. The "Dmp CC No." parameter specifies the controller to be used for damping control. When set to "off," no damping variation can be applied via a controller. Details • Note that accurate keyboard pitch is pro- duced only when damping is maximum. • The "DmpCtrlDpt" parameter (below) must be set to an appropriate value (higher than "+01" or lower than "-01") for damping control to have any effect. "Absorption" simulates the effect of highfrequency loss at the end of the air column or string. The "Abs CC No." parameter specifies the controller to be used for absorption control. When set to "off," no absorption variation can be applied via a controller. Details • Note that accurate keyboard pitch is pro- duced only at when absorption is maximum. • The "AbsCtrlDpt" parameter (below) must be set to an appropriate value (higher than "+01" or lower than "-01") for absorption control to have any effect. 124 Multi Mode

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200

124
Multi Mode
Harmonic Enhancer Control Depth
(HrmCtrlDpt)
Settings:
-64 — +63
Sets the amount of variation produced by
the controller assigned to the harmonic
enhancer. The higher the value, the greater
the variation. Positive values cause an
increase in harmonic enhancer depth in
response to higher controller values (e.g.,
increased breath pressure or higher modu-
lation wheel position), while negative
values cause a decrease in harmonic en-
hancer depth in response to higher con-
troller values.
Damping
Damping Control Change Number
(Dmp CC No.)
Settings:
off, 01 — 31, off, 33 — 95,
AT, VEL, PB
“Damping” simulates the effect of damp-
ing due to losses within the body of a wind
instrument or in a string due to air fric-
tion.
This affects both pitch and timbre.
The “Dmp CC No.” parameter specifies
the controller to be used for damping con-
trol. When set to “off,” no damping varia-
tion can be applied via a controller.
Details
• Note that accurate keyboard pitch is pro-
duced only when damping is maximum.
The “DmpCtrlDpt” parameter (below) must
be set to an appropriate value (higher than
“+01” or lower than “-01”) for damping
control to have any effect.
Damping Control Depth (DmpCtrlDpt)
Settings:
-64 — +63
Sets the amount of variation produced by
the controller assigned to damping. The
higher the value, the greater the variation.
Positive values cause a decrease in damp-
ing in response to higher controller val-
ues (e.g., increased breath pressure or
higher modulation wheel position), while
negative values cause an increase in
damping in response to higher controller
values.
Absorption
Apsorption Control Change Number
(Abs CC No.)
Settings:
off, 01 — 31, off, 33 — 95,
AT, VEL, PB
“Absorption” simulates the effect of high-
frequency loss at the end of the air col-
umn or string. The “Abs CC No.” param-
eter specifies the controller to be used for
absorption control. When set to “off,” no
absorption variation can be applied via a
controller.
Details
• Note that accurate keyboard pitch is pro-
duced only at when absorption is maxi-
mum.
The “AbsCtrlDpt” parameter (below) must
be set to an appropriate value (higher than
“+01” or lower than “-01”) for absorption
control to have any effect.
Multi Edit Mode