Yamaha MU100R MU100R Owners Manual - Page 65

Control Numbers and the Actual Sound

Page 65 highlights

Assignable Controller (AC1) The actual, physical means of controlling (such as foot pedals, modulation wheels, etc. on a connected keyboard) are generally assigned to specific "virtual" control numbers. A few examples of these include the modulation wheel (at control number 1), foot controller (control number 4), and volume pedal (control number 7).* Physical controller (volume pedal) MIDI OUT PITCH SHIFT ASSIGNABLE CONTROLLER NUMBER LIST CONTROL CHANGE 1 MODULATION DEPTH 2 BREATH CONTROL 4 FOOT CONTROL 5 PORTAMENTO TIME 6 DATA ENTRY 7 MAIN VOLUME 8 BALANCE CONTROL 10 PANPOT 11 EXPRESSION 64 HOLD1(DAMPER) 65 PORTAMENTO 66 SOSTENUTO(CHORD HOLD) 67 SOFT PEDAL 69 HOLD2 (FREEZE) 71 HARMONIC CONTENT 72 RELEASE TIME 73 ATTACK TIME 74 BRIGHTNESS 84 PORTAMENTO CONTROL 91 REVERB DEPTH 92 TREMOLO DEPTH 93 CHORUS DEPTH 94 VARIATION DEPTH 95 PHASER DEPTH (RPN) 120 PITCH BEND SENSITIVITY 121 FINE TUNING 122 COARSE TUNING (NRPN) 123 VIBRATO RATE 124 VIBRATO DEPTH 125 VIBRATO DELAY IN MIDI OUT DC IN POWER ON OFF 126 FILTER CUTOFF FREQUENCY 127 FILTER RESONANCE 128 EG ATTACK TIME 129 EG DECAY TIME 130 EG RELEASE TIME 131 DRUM FILTER CUTOFF FREQUENCY 132 DRUM FILTER RESONANCE 133 DRUM EG ATTACK RATE 134 DRUM EG DECAY RATE 135 DRUM PITCH COARSE 136 DRUM PITCH FINE 137 DRUM LEVEL 138 DRUM PAN 139 DRUM REVERB DEPTH 140 DRUM CHORUS DEPTH 141 DRUM VARIATION DEPTH OTHERS 142 CHANNEL PRESSURE 143 POLYPHONIC KEY PRESSURE 144 MASTER VOLUME 145 MASTER BALANCE 146 MASTER TUNING 147 VELOCITY 148 TEMPO SEQUENCER PROGRAM RESET SYSTEM WHEEL ASSIGN TRANSPOSE BANK PROGRAM GM SOUND STOP CONTINUE START TEMPO SELECT CHANGE ON OFF XG MERGE MIDI FIXED DRUM ON ON/OFF CH VELOCITY RPN CONTROLLER NRPN NUMBER 1 2 3 4 5 6 7 8 9 A B C D E MIDI KEYBOARD CBX-K1 ENTER HEXA F 0 DECIMAL DECIMAL OCTAVE OCTAVE SHIFT OCTAVE RESET "Virtual" controller: control number 7 (MIDI Volume) MIDI Keyboard * On some instruments, the control number for the physical controllers is fixed; some instruments allow you to assign a different control number to the existing control. (Refer to the owner's manual of your instrument for details. Also for more on control numbers, see the list on page 126 of this manual, and the "Sound List & MIDI Data" booklet.) Control Numbers and the Actual Sound The control numbers described above are in turn assigned to some specific aspect of the sound on the connected tone generator (for example, to volume, pitch modulation, dry/wet balance of an effect, etc.). As you might expect, control number 7 (Volume) affects the volume of the connected tone generator. MIDI OUT PITCH SHIFT ASSIGNABLE CONTROLLER NUMBER LIST CONTROL CHANGE 1 MODULATION DEPTH 2 BREATH CONTROL 4 FOOT CONTROL 5 PORTAMENTO TIME 6 DATA ENTRY 7 MAIN VOLUME 8 BALANCE CONTROL 10 PANPOT 11 EXPRESSION 64 HOLD1(DAMPER) 65 PORTAMENTO 66 SOSTENUTO(CHORD HOLD) 67 SOFT PEDAL 69 HOLD2 (FREEZE) 71 HARMONIC CONTENT 72 RELEASE TIME 73 ATTACK TIME 74 BRIGHTNESS 84 PORTAMENTO CONTROL 91 REVERB DEPTH 92 TREMOLO DEPTH 93 CHORUS DEPTH 94 VARIATION DEPTH 95 PHASER DEPTH (RPN) 120 PITCH BEND SENSITIVITY 121 FINE TUNING 122 COARSE TUNING (NRPN) 123 VIBRATO RATE 124 VIBRATO DEPTH 125 VIBRATO DELAY IN MIDI OUT DC IN POWER ON OFF 126 FILTER CUTOFF FREQUENCY 127 FILTER RESONANCE 128 EG ATTACK TIME 129 EG DECAY TIME 130 EG RELEASE TIME 131 DRUM FILTER CUTOFF FREQUENCY 132 DRUM FILTER RESONANCE 133 DRUM EG ATTACK RATE 134 DRUM EG DECAY RATE 135 DRUM PITCH COARSE 136 DRUM PITCH FINE 137 DRUM LEVEL 138 DRUM PAN 139 DRUM REVERB DEPTH 140 DRUM CHORUS DEPTH 141 DRUM VARIATION DEPTH OTHERS 142 CHANNEL PRESSURE 143 POLYPHONIC KEY PRESSURE 144 MASTER VOLUME 145 MASTER BALANCE 146 MASTER TUNING 147 VELOCITY 148 TEMPO SEQUENCER PROGRAM RESET SYSTEM WHEEL ASSIGN TRANSPOSE BANK PROGRAM GM SOUND XG MERGE MIDI FIXED DRUM STOP CONTINUE START TEMPO SELECT CHANGE ON OFF ON ON/OFF CH VELOCITY RPN CONTROLLER NRPN NUMBER 1 2 3 4 5 6 7 8 9 A B C D E MIDI KEYBOARD CBX-K1 ENTER HEXA F 0 DECIMAL DECIMAL OCTAVE OCTAVE SHIFT OCTAVE RESET MIDI IN POWER ON/ OFF MU100R MIDI Keyboard In this example, the foot controller of a keyboard controls the volume on the MU100R. 54 Guided Tour

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200

54
Guided Tour
The actual, physical means of controlling (such as foot pedals, modulation
wheels, etc. on a connected keyboard) are generally assigned to specific
“virtual” control numbers. A few examples of these include the modulation
wheel (at control number 1), foot controller (control number 4), and volume
pedal (control number 7).*
Control Numbers and the Actual Sound
The control numbers described above are in turn assigned to some specific
aspect of the sound on the connected tone generator (for example, to vol-
ume, pitch modulation, dry/wet balance of an effect, etc.). As you might
expect, control number 7 (Volume) affects the volume of the connected tone
generator.
Physical controller
(volume pedal)
In this example, the foot controller of a keyboard controls the volume on the MU100R.
Assignable Controller (AC1)
*
On some instruments, the control number for the physical controllers
is fixed; some instruments allow you to assign a different control
number to the existing control. (Refer to the owner’s manual of your
instrument for details. Also for more on control numbers, see the list
on page 126 of this manual, and the “Sound List & MIDI Data” book-
let.)
TRANSPOSE
DC IN
OCTAVE
OCTAVE SHIFT
OCTAVE
RESET
PITCH
ASSIGNABLE
IN
MIDI
OUT
ENTER
PROGRAM
RESET
SYSTEM
WHEEL ASSIGN
SEQUENCER
POWER ON
OFF
SHIFT
MIDI
KEYBOARD
CBX-K1
CONTROLLER
NUMBER
LIST
“Virtual” controller:
control number 7
(MIDI Volume)
TRANSPOSE
DC IN
OCTAVE
OCTAVE SHIFT
OCTAVE
RESET
PITCH
ASSIGNABLE
IN
MIDI
OUT
ENTER
PROGRAM
RESET
SYSTEM
WHEEL ASSIGN
SEQUENCER
POWER ON
OFF
SHIFT
MIDI
KEYBOARD
CBX-K1
CONTROLLER
NUMBER
LIST
MIDI Keyboard
MIDI OUT
MIDI Keyboard
MU100R
MIDI IN
MIDI OUT