3550-US-5.0 REGULAR MAINTENANCE AND TROUBLESHOOTING 13. REGULAR MAINTENANCE AND TROUBLESHOOTING Regular Maintenance You can keep your fax machine in optimum condition by cleaning it on a regular basis. It is a good idea to replace the toner cartridge and the drum unit during this routine. Avoid using thinners or other organic solvents to clean the machine and do not use water. Follow the four steps below: 1. Unplug the telephone line and then the power cord. When you reconnect these lines later, make sure to connect the power cord first, then the telephone line. 2. Wipe dirt off the machine using a slightly damp clean cloth. 3. Clean the white plate and the glass cover: Moisten a small piece of clean soft, lint-free cloth with isopropyl alcohol and carefully remove dirt from the glass cover and the white plate of the scanner. * Donotuseisopropylalcoholtoremovedirtfromthecontrolpanel. Itmaycauseacrackonthe panel. 4. Wipethegears(seepage13-2)andelectricterminalswithisopropylalcoholonacottonswab. Gently wipe the scanner window and toner sensor with a clean soft dry cloth. Control panel White plate Control panel Open the control panel. Glass cover Ch.13 13-1