Cisco SPA112 Administration Guide - Page 80

Control Timer Values sec, Ring Voltage: 80Vc

Page 80 highlights

Configuring Voice Configuring Voice Settings 4 - Ring Frequency: 25 - Ring Voltage: 80Vc Field Description Ring Waveform Waveform for the ringing signal. Choices are Sinusoid or Trapezoid. Default setting: Sinusoid. Ring Frequency Frequency of the ringing signal. Valid values are 10-100 (Hz) Default setting: 20. Ring Voltage Ringing voltage. Choices are 60-90 (V) Default setting: 85. CWT Frequency Frequency script of the call waiting tone. All distinctive CWTs are based on this tone. Default setting: 440@-10. Synchronized Ring If this is set to Yes, when the ATA is called, all lines ring at the same time (similar to a regular PSTN line) After one line answers, the others stop ringing. Default setting: no. Control Timer Values (sec) Field Hook Flash Timer Min Hook Flash Timer Max Callee On Hook Delay Reorder Delay Call Back Expires Description Minimum on-hook time before off-hook qualifies as hookflash. Less than this the on-hook event is ignored. Range: 0.1-0.4 seconds. Default setting: 0.1. Maximum on-hook time before off-hook qualifies as hookflash. More than this the on-hook event is treated as onhook (no hook-flash event) Range: 0.4-1.6 seconds. Default setting: 0.9. Phone must be on-hook for at this time in sec. before the ATA will tear down the current inbound call. It does not apply to outbound calls. Range: 0-255 seconds. Default setting: 0. Delay after far end hangs up before reorder tone is played. 0 = plays immediately, inf = never plays. Range: 0-255 seconds. Default setting: 5. Expiration time in seconds of a call back activation. Range: 0-65535 seconds. Default setting: 1800. Cisco SPA100 Series Phone Adapters Administration Guide 80

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147

Configuring Voice
Configuring Voice Settings
Cisco SPA100 Series Phone Adapters Administration Guide
80
4
-
Ring Frequency: 25
-
Ring Voltage: 80Vc
Control Timer Values (sec)
Field
Description
Ring Waveform
Waveform for the ringing signal. Choices are Sinusoid
or
Trapezoid.
Default setting: Sinusoid.
Ring Frequency
Frequency of the ringing signal. Valid values are 10–100 (Hz)
Default setting: 20.
Ring Voltage
Ringing voltage. Choices are
60–90
(V)
Default setting: 85.
CWT Frequency
Frequency script of the call waiting tone. All distinctive
CWTs are based on this tone. Default setting: 440@-10.
Synchronized
Ring
If this is set to Yes, when the ATA is called, all lines ring at the
same time (similar to a regular PSTN line) After one line
answers, the others stop ringing.
Default setting: no.
Field
Description
Hook Flash Timer
Min
Minimum on-hook time before off-hook qualifies as
hookflash. Less than this the on-hook event is ignored.
Range: 0.1–0.4 seconds. Default setting: 0.1.
Hook Flash Timer
Max
Maximum on-hook time before off-hook qualifies as
hookflash. More than this the on-hook event is treated as
onhook (no hook-flash event) Range: 0.4–1.6 seconds.
Default setting: 0.9.
Callee On Hook
Delay
Phone must be on-hook for at this time in sec. before the
ATA will tear down the current inbound call. It does not
apply to outbound calls. Range: 0–255 seconds. Default
setting:
0
.
Reorder Delay
Delay after far end hangs up before reorder tone is
played. 0 = plays immediately, inf = never plays. Range:
0–255 seconds. Default setting: 5.
Call Back Expires
Expiration time in seconds of a call back activation.
Range: 0–65535 seconds. Default setting: 1800.