Dell PowerVault 56F Dell PowerVault 51F 8-Port Fibre Channel Switch Insta - Page 104

uRouteShow

Page 104 highlights

uRouteShow Figure 4-5 shows the uRouteShow command, which displays the port's unicast routing information, which is the output port used to forward frames to the domain. Only one output port is used to forward frames from one input port to a destination domain. The command uRouteShow now has three different syntax options: • uRouteShow , - displays the route for port to domain • uRouteShow - displays the route for port to all the active domains in the fabric • uRouteShow - displays the route for all the ports on the switch to all the active domains in the fabric In addition, in all three formats uRouteShow shows for each route, the domain ID of the next hop, and the port number on the next hop. Local Domain ID: 1 In Port Domain Out Port Metric Hops Flags Next (Dom, Port 0 5 7 1000 1 D 5,6 6 7 2000 2 D 5,6 7 7 3000 3 D 5,6 8 7 4000 4 D 5,6 9 7 5000 5 D 5,6 1 5 5 1000 1 D 5,5 6 5 2000 2 D 5,5 7 5 3000 3 D 5,5 8 5 4000 4 D 5,5 9 5 5000 5 D 5,5 2 5 4 1000 1 D 5,4 6 4 2000 2 D 5,4 7 4 3000 3 D 5,4 8 4 4000 4 D 5,4 9 4 5000 5 D 5,4 value = 1 = 0x1 Figure 4-5. uRouteShow Command Example 4-42 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

4-42
Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide
uRouteShow
Figure 4-5 shows the
uRouteShow
command, which displays the port's unicast rout-
ing information, which is the output port used to forward frames to the domain. Only
one output port is used to forward frames from one input port to a destination
domain.
The command
uRouteShow
now has three different syntax options:
uRouteShow <
port number
>, <
domain ID
>
displays the route for port
<port #> to domain <domain ID>
uRouteShow <
port number
>
displays the route for port <port #> to all the
active domains in the fabric
uRouteShow
displays the route for all the ports on the switch to all the active
domains in the fabric
In addition, in all three formats
uRouteShow
shows for each route, the domain ID of
the next hop, and the port number on the next hop.
Figure 4-5.
uRouteShow Command Example
Local Domain ID: 1
In Port
Domain
Out Port
Metric
Hops
Flags
Next (Dom, Port
---------------------------------------------------------------------------
0
5
7
1000
1
D
5,6
6
7
2000
2
D
5,6
7
7
3000
3
D
5,6
8
7
4000
4
D
5,6
9
7
5000
5
D
5,6
1
5
5
1000
1
D
5,5
6
5
2000
2
D
5,5
7
5
3000
3
D
5,5
8
5
4000
4
D
5,5
9
5
5000
5
D
5,5
2
5
4
1000
1
D
5,4
6
4
2000
2
D
5,4
7
4
3000
3
D
5,4
8
4
4000
4
D
5,4
9
4
5000
5
D
5,4
value = 1 = 0x1