switchShow, Must have the first character be among a-z or A-Z.

Page 91 highlights

Certain restrictions apply to the length and format of the switch name. Specifically, the name of the switch: • May not exceed 19 characters in length. • May not contain characters other than a-z, A-Z, 0-9 or _ (the underscore charac- ter), the first character excepted. • Must have the first character be among a-z or A-Z. NOTE: It is suggested that switch names be unique in a cascaded environment. switchShow The following example shows the switchShow command screen, which prints switch and port status. The fields are described in Table 4-16. switch:admin> switchShow switchName: open146 switchType: 3.1 switchState: Online switchRole: Principal switchDomain: 1 switchId: fffc41 switchWwn: 10:00:00:60:69:00:04:64 port 0: sw Online FL-Port 1 private, 1 phantom port 1: -- No_Module G-Port port 2: sw No_Light G-Port port 3: sw Online FL-Port 1 private, 1 phantom port 4: -- No_Module port 5: sw Online E-Port 10:00:00:60:69:00:00:12 "sw1" (upstrea port 6: sw No_Light port 7: sw No_Light port 8: sw No_Light port 9: sw Online E-Port 10:00:00:60:69:00:01:b4 "sw3" (downstr port 10: sw No_Light port 11: sw No_Light port 12: sw No_Light port 13: sw No_Light port 14: sw No_Light port 15: sw No_Light support.dell.com PowerVault 51F Commands 4-29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

support.dell.com
PowerVault 51F Commands
4-29
Certain restrictions apply to the length and format of the switch name. Specifically,
the name of the switch:
May not exceed 19 characters in length.
May not contain characters other than a-z, A-Z, 0-9 or _ (the underscore charac-
ter), the first character excepted.
Must have the first character be among a-z or A-Z.
NOTE: It is suggested that switch names be unique in a cascaded environment.
switchShow
The following example shows the
switchShow
command screen, which prints
switch and port status. The fields are described in Table 4-16.
switch:admin> switchShow
switchName:
open146
switchType:
3.1
switchState:
Online
switchRole:
Principal
switchDomain:
1
switchId:
fffc41
switchWwn:
10:00:00:60:69:00:04:64
port
0: sw
Online
FL-Port
1 private, 1 phantom
port
1: --
No_Module
G-Port
port
2: sw
No_Light
G-Port
port
3: sw
Online
FL-Port
1 private, 1 phantom
port
4: --
No_Module
port
5: sw
Online
E-Port
10:00:00:60:69:00:00:12 "sw1" (upstrea
port
6: sw
No_Light
port
7: sw
No_Light
port
8: sw
No_Light
port
9: sw
Online
E-Port
10:00:00:60:69:00:01:b4 "sw3" (downstr
port 10: sw
No_Light
port 11: sw
No_Light
port 12: sw
No_Light
port 13: sw
No_Light
port 14: sw
No_Light
port 15: sw
No_Light