Other Possible Errors, Fan Error Message
View all Dell PowerVault 56F manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 147 highlights
support.dell.com Table A-3. Commands to Gather MQ-QWRITE Error Information (continued) Command Description spyStop Stops microprocessor utilization monitoring. This command can be typed in at any time during the monitoring process. For information on executing these commands, contact Dell for technical assistance. Other Possible Errors This section explains the other errors that may occur. Fan Error Message Fan has stopped spinning: Please check the fans inside the switch box. Port Error Messages The GBIC was removed from this port (Solid Black LED): Please check the switch front panel for GBICs. Port is receiving no signal (Solid Black LED): There is no G_Port board or no GBIC module for this port. Please check the switch front panel. Port is receiving signal, but not yet online (Solid Amber LED): Cable is partially inserted in the port, or the device at the other end of the cable is not functioning properly. Please check the switch front panel or check the device on the other end of the cable. Port is disabled (Slow Flashing Amber LED): The port was disabled by an administrator manually via the front panel, or via one of the management tools. Port has a fault (Fast Flashing Amber LED): One or more faulty conditions have occurred: Laser_Flt: the module is signaling a laser fault (defective GBIC); Port_Flt: the port has been marked faulty (defective GBIC, cable or device) Error Messages A-9