Dell PowerVault 56F Dell PowerVault 51F 8-Port Fibre Channel Switch Insta - Page 94

uptime, version, License Commands, Table 4-17., version Command Field Descriptions

Page 94 highlights

switch:admin> tempShow 31 27 28 27 33 Centigrade 87 80 82 80 91 Fahrenheit uptime The uptime command can be used to display the amount of time the switch has been in operation (also known as up time), the total cumulative amount of up time since the switch was first powered-on, the date and time of the last reboot, and the reason for the last reboot. For up and powered-on times less than 60 seconds, the display granularity is by the second. For times greater than 60 seconds, the display granularity is by the minute. In addition, the formatting of the output adjusts based on the amount of time. See Appendix A, "Error Messages," for more information. version The following example shows the version command screen, which displays firmware version information and build dates. The fields are described in Table 4-17. switch:admin> version VxWorks version: 5.3.1 Firmware version: v2.0 Made on: Thu Nov 19 16:18:29 PST 1998 Flash: Mon Dec 28 15:34:05 PST 1998 BootProm: Thu Oct 1 13:34:29 PDT 1998 Table 4-17. version Command Field Descriptions Field Description VxWorks version VxWorks operating environment version used on the processor Firmware version Switch firmware version Made on Firmware release date and time Flash The build date of the firmware stored in flash memory BootProm The build date of the firmware stored in the boot PROM License Commands License commands are reserved for use by Dell only. 4-32 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

4-32
Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide
uptime
The
uptime
command can be used to display the amount of time the switch has been
in operation (also known as up time), the total cumulative amount of up time since the
switch was first powered-on, the date and time of the last reboot, and the reason for
the last reboot.
For up and powered-on times less than 60 seconds, the display granularity is by the
second. For times greater than 60 seconds, the display granularity is by the minute. In
addition, the formatting of the output adjusts based on the amount of time. See
Appendix A, “Error Messages,” for more information.
version
The following example shows the
version
command screen, which displays firmware
version information and build dates. The fields are described in Table 4-17.
License Commands
License commands are reserved for use by Dell only.
Table 4-17.
version Command Field Descriptions
Field
Description
VxWorks version
VxWorks operating environment version used on the
processor
Firmware
version
Switch firmware version
Made on
Firmware release date and time
Flash
The build date of the firmware stored in flash memory
BootProm
The build date of the firmware stored in the boot PROM
switch:admin> tempShow
31
27
28
27
33
Centigrade
87
80
82
80
91
Fahrenheit
switch:admin> version
VxWorks version: 5.3.1
Firmware version: v2.0
Made on: Thu Nov 19 16:18:29 PST 1998
Flash:
Mon Dec 28 15:34:05 PST 1998
BootProm:
Thu Oct 1 13:34:29 PDT 1998