Dell PowerVault 56F Dell PowerVault 51F 8-Port Fibre Channel Switch Insta - Page 93

syslogdIp, tempShow

Page 93 highlights

Table 4-16. switchShow Command Field Descriptions (continued) Field Description Port state The port state follows the GBIC type. The possible port states include: • No_Card - No card present in this switch slot • No_Module - No GBIC module in this port • No_Light - The module is not receiving light • No_Sync - The module is receiving light but is out of sync • In_Sync - The module is receiving light and is in sync • Laser_Flt - The module is signaling a laser fault (defec- tive GBIC) • Port_Flt - The port has been marked faulty (defective GBIC, cable, or device) • Diag_Flt - The port failed diagnostics (defective G_Port or FL_Port card or system board) • Online - The port is up and running • Lock_Ref - The port locking to the reference signal • Testing - Running diagnostics Comment field The comment field follows the port state. The possible comments include: • Disabled - The port is disabled • Loopback - The port is in loopback mode • E_Port - The WWN and switch name of the other switch is shown, the use of this Inter Switch Link (ISL) is shown (see FC_SW) • F_Port - The WWN of the N_Port is shown • G_Port - The port is online but is not yet an E_Port or F_Port • L_Port - The port is connected to an arbitrated loop syslogdIp The syslogdIp command sets or displays the switches system log daemon IP address. The command syntax is syslogdip . tempShow The following example shows the tempShow command screen, which shows the switch's temperature as measured by five sensors on the system board. support.dell.com PowerVault 51F Commands 4-31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

support.dell.com
PowerVault 51F Commands
4-31
syslogdIp
The
syslogdIp
command sets or displays the switches system log daemon IP
address. The command syntax is
syslogdip <
ip address
>.
tempShow
The following example shows the
tempShow
command screen, which shows the
switch’s temperature as measured by five sensors on the system board.
Port state
The port state follows the GBIC type. The possible port states
include:
No_Card — No card present in this switch slot
No_Module — No GBIC module in this port
No_Light — The module is not receiving light
No_Sync — The module is receiving light but is out of
sync
In_Sync — The module is receiving light and is in sync
Laser_Flt — The module is signaling a laser fault (defec-
tive GBIC)
Port_Flt — The port has been marked faulty (defective
GBIC, cable, or device)
Diag_Flt — The port failed diagnostics (defective G_Port
or FL_Port card or system board)
Online — The port is up and running
Lock_Ref — The port locking to the reference signal
Testing — Running diagnostics
Comment field
The comment field follows the port state. The possible com-
ments include:
Disabled
The port is disabled
Loopback
The port is in loopback mode
E_Port
The WWN and switch name of the other
switch is shown, the use of this Inter Switch Link (ISL) is
shown (see FC_SW)
F_Port
The WWN of the N_Port is shown
G_Port
The port is online but is not yet an E_Port or
F_Port
L_Port
The port is connected to an arbitrated loop
Table 4-16.
switchShow Command Field Descriptions
(continued)
Field
Description