Dell PowerVault 56F Dell PowerVault 51F 8-Port Fibre Channel Switch Insta - Page 60
Name Server, See Appendix A, Error Messages, for more information.
View all Dell PowerVault 56F manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
2 - Error 3 - Warning 4 - Informational 5 - Debug See Appendix A, "Error Messages," for more information. These parameters can be changed via the Telnet command, agtcfgSet or via SNMP. The sysX parameters can be configured via the SNMPv1 SET command with an appropriate community. These parameters can be configured via a Telnet connection, using the command agtcfgSet. NOTE: A change in the first two configuration parameters takes effect only after rebooting the switch. Name Server The Fibre Channel Protocol (FCP) inquiry data obtained by device probing may now be obtained from the Name Server by retrieving the port symbolic name. Common Transport (CT) requests and responses including Name Server are recorded in the portLog. A typical trace is shown in the following example, where port 4 logs in to the Name Server and issues command 217. It receives an Accept (8002). Jun 15 16:00:21.899 tReceive 22fffffc,00210413,03000000 Jun 15 16:00:21.899 tSwitch 23210413,00fffffc,02000000 Jun 15 16:00:21.899 tReceive 02fffffc,00210413,01000000 Jun 15 16:00:21.933 tNSd 00030217,00210413,00000100 Jun 15 16:00:21.933 tNSd Jun 15 16:00:21.933 tNSd 03210413,00fffffc Rx3 Tx3 Rx3 ctin ctout Tx3 4 116 4 116 4 52 4 fc 4 fc 00008002 4 0 3-8 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide