HP 6125G HP 6125G & 6125G/XG Blade Switches Fundamentals Command Refer - Page 156

display transceiver diagnosis, Table 27, Command output

Page 156 highlights

display transceiver alarm interface gigabitethernet 1/0/3 GigabitEthernet1/0/3 transceiver current alarm information: RX loss of signal RX power low Table 27 Command output Field transceiver current alarm information RX loss of signal RX power low Description Alarms present on the transceiver module. Incoming (RX) signal is lost. Incoming (RX) power level is low. display transceiver diagnosis Syntax View display transceiver diagnosis interface [ interface-type interface-number ] [ | { begin | exclude | include } regular-expression ] Any view Default level 2: System level Parameters interface [ interface-type interface-number ]: Displays the present measured values of the digital diagnosis parameters for the transceiver module in the specified interface. The interface-type interface-number argument specifies an interface by its type and number. If no interface is specified, the command displays the present measured values of the digital diagnosis parameters for all transceiver modules. |: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide. begin: Displays the first line that matches the specified regular expression and all lines that follow. exclude: Displays all lines that do not match the specified regular expression. include: Displays all lines that match the specified regular expression. regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters. Description Use display transceiver diagnosis to display the present measured values of the digital diagnosis parameters for transceiver modules. Examples # Display the present measured values of the digital diagnosis parameters for the transceiver module in GigabitEthernet 1/0/3. display transceiver diagnosis interface gigabitethernet 1/0/3 GigabitEthernet1/0/3 transceiver diagnostic information: Current diagnostic parameters: Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm) 149

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

149
<Sysname> display transceiver alarm interface gigabitethernet 1/0/3
GigabitEthernet1/0/3 transceiver current alarm information:
RX loss of signal
RX power low
Table 27
Command output
Field
Description
transceiver current alarm information
Alarms present on the transceiver module.
RX loss of signal
Incoming (RX) signal is lost.
RX power low
Incoming (RX) power level is low.
display transceiver diagnosis
Syntax
display transceiver diagnosis interface
[
interface-type interface-number
] [
|
{
begin
|
exclude
|
include
}
regular-expression
]
View
Any view
Default level
2: System level
Parameters
interface
[
interface-type interface-number
]: Displays the present measured values of the digital
diagnosis parameters for the transceiver module in the specified interface. The
interface-type
interface-number
argument specifies an interface by its type and number. If no interface is specified, the
command displays the present measured values of the digital diagnosis parameters for all transceiver
modules.
|
: Filters command output by specifying a regular expression. For more information about regular
expressions, see
Fundamentals Configuration Guide
.
begin
: Displays the first line that matches the specified regular expression and all lines that follow.
exclude
: Displays all lines that do not match the specified regular expression.
include
: Displays all lines that match the specified regular expression.
regular-expression
: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use
display transceiver diagnosis
to display the present measured values of the digital diagnosis
parameters for transceiver modules.
Examples
# Display the present measured values of the digital diagnosis parameters for the transceiver module in
GigabitEthernet 1/0/3.
<Sysname> display transceiver diagnosis interface gigabitethernet 1/0/3
GigabitEthernet1/0/3 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C)
Voltage(V)
Bias(mA)
RX power(dBm)
TX power(dBm)