HP Scitex LX600 HP Scitex LX Printer Family - User's guide - Page 11

Electrical shock hazard, Heat hazard, Fire hazard

Page 11 highlights

◦ Fuses have blown. ◦ The printer is not operating normally. ● Turn off the printer using both Branch Circuit Breakers in either of the following cases: ◦ During a thunderstorm ◦ During a power failure Electrical shock hazard WARNING! The internal circuits and drying and curing modules operate at hazardous voltages capable of causing death or serious personal injury. Turn off the printer using both Branch Circuit Breakers located in the building's Power Distribution Unit (PDU) before servicing the printer. The printer must be connected to earthed mains outlets only. To avoid the risk of electric shock: ● Do not attempt to dismantle the drying and curing modules or the electrical control cabinet. ● Do not remove or open any other closed system covers or plugs. ● Do not insert objects through slots in the printer. NOTE: A blown fuse may indicate malfunctioning electrical circuits within the system. Call your service representative, and do not attempt to replace the fuse yourself. Heat hazard The drying and curing subsystems of the printer operate at high temperatures and can cause burns if touched. To avoid personal injury, take the following precautions. ● Do not touch the internal enclosures of the printer's drying and curing modules. ● Take special care when accessing the substrate path. Fire hazard The drying and curing subsystems of the printer operate at high temperatures. Call your service representative if the printer's built-in Residual Current Circuit Breaker (Ground Fault Circuit Interrupter) is repeatedly tripped. To avoid the risk of fire, take the following precautions. ● Do not insert objects through slots in the printer. ● Take care not to spill liquid on the printer. ● Do not use aerosol products that contain flammable gases inside or around the printer. ● Do not block or cover the openings of the printer. ● Do not attempt to dismantle the drying or curing module, or the electrical control cabinet. ● Load substrates that can be used at an operating temperature of up to 125°C (257°F), and have auto-ignition temperatures above 250°C (482°F). ENWW Safety precautions 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

Fuses have blown.
The printer is not operating normally.
Turn off the printer using both Branch Circuit Breakers in either of the following cases:
During a thunderstorm
During a power failure
Electrical shock hazard
WARNING!
The internal circuits and drying and curing modules operate at hazardous voltages
capable of causing death or serious personal injury.
Turn off the printer using both Branch Circuit Breakers located in the building's Power Distribution Unit
(PDU) before servicing the printer. The printer must be connected to earthed mains outlets only.
To avoid the risk of electric shock:
Do not attempt to dismantle the drying and curing modules or the electrical control cabinet.
Do not remove or open any other closed system covers or plugs.
Do not insert objects through slots in the printer.
NOTE:
A blown fuse may indicate malfunctioning electrical circuits within the system. Call your service
representative, and do not attempt to replace the fuse yourself.
Heat hazard
The drying and curing subsystems of the printer operate at high temperatures and can cause burns if
touched. To avoid personal injury, take the following precautions.
Do not touch the internal enclosures of the printer's drying and curing modules.
Take special care when accessing the substrate path.
Fire hazard
The drying and curing subsystems of the printer operate at high temperatures. Call your service
representative if the printer's built-in Residual Current Circuit Breaker (Ground Fault Circuit Interrupter)
is repeatedly tripped.
To avoid the risk of fire, take the following precautions.
Do not insert objects through slots in the printer.
Take care not to spill liquid on the printer.
Do not use aerosol products that contain flammable gases inside or around the printer.
Do not block or cover the openings of the printer.
Do not attempt to dismantle the drying or curing module, or the electrical control cabinet.
Load substrates that can be used at an operating temperature of up to 125°C (257°F), and have
auto-ignition temperatures above 250°C (482°F).
ENWW
Safety precautions
7