HP Scitex LX600 HP Scitex LX Printer Family - User's guide - Page 94
Air supply requirements (pneumatic spindle), Air pressure supply, Pneumatic connector
View all HP Scitex LX600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
Table 7-11 LX800 single-phase circuit breaker specifications High-voltage systems Input voltage (line to line) 200-240 V~ (-10%+6%) Input frequency 50 Hz Single-phase branch circuit breaker 2 poles, 20 A Low-voltage systems 115-127 V~ (±10%) (Japan 200 V~) 60 Hz 2 poles, 20 A Air supply requirements (pneumatic spindle) Air pressure supply The pneumatic spindle requires an air compressor or a pressurized air line, not supplied with the printer. TIP: You are recommended to use a pressure gauge that indicates the pressure in bars. Table 7-12 Air supply specifications Air pressure Minimum airflow Lubricator Air filter (recommended) Regulator (required) 5.5 bar (80 psi) Recommendation: 30 l/min Not recommended Recommendation: 5 µm, auto-drain, 99.97% coalescing efficiency Regulator with pressure gauge Pneumatic connector The printer comes with an air gun that you must attach to your air supply. In order to connect your air supply to the air gun, you must meet the following requirements: ● 9.84-mm (0.25-in) female connector, BSP or NPT thread ● Teflon tape to secure the connection and prevent air leaks Ecological specifications For the up-to-date ecological specifications of your printer, please go to http://www.hp.com/ and search for "ecological specifications". Environmental specifications Table 7-13 Printer environmental specifications Temperature range Operating for optimal print quality Operating for standard printing 20 to 25°C (68 to 77°F) 15 to 30°C (59 to 86°F) Humidity range Temperature gradient 40 to 60% Relative Humidity 10°C/h (50°F/h) or less 20 to 70% Relative Humidity 10°C/h (50°F/h) or less 90 Chapter 7 Printer specifications ENWW