Toshiba Portege M100 Maintenance Manual - Page 73
Procedure 3, Connector Check and Replacement Check, FDD Troubleshooting, Troubleshooting Procedures
View all Toshiba Portege M100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
2.5 FDD Troubleshooting 2 Troubleshooting Procedures Procedure 3 Connector Check and Replacement Check The 3.5inch FDD is connected to the System Board via USB port. Check 1 Make sure the USB cable is securely connected to the FDD. Also, check the cables between connector board, I/O board and system board. • Whether cables are disconnected • Whether connectors are squarely connected • Whether connectors are firmly connected • Whether connectors are defective If any of the connections are loose, reconnect firmly and repeat Procedure 2. If any connector is damaged, replace it with a ne w one and repeat Procedure 2. If there is still an error, go to Check 2. Check 2 The FDD cable may be defective or damaged. Replace it with a new one following the steps in Chapter 4, Replacement Procedures. If the FDD is still not functioning properly, perform Check 3. Check 3 Replace the System board with a new one following the steps in Chapter 4, Replacement Procedures. PORTEGE M100 Maintenance Manual (960-452) 2-31