Toshiba Portege M100 Maintenance Manual - Page 77
Procedure 4, Diagnostic Test Program Execution Check, HDD Troubleshooting, Troubleshooting Procedures
View all Toshiba Portege M100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
2.6 HDD Troubleshooting 2 Troubleshooting Procedures Procedure 4 Diagnostic Test Program Execution Check The HDD test program is stored in the Diagnostics Disk. Perform all of the HDD tests in the Hard Disk Drive Test. Refer to Chapter 3, Tests and Diagnostics, for more information about the HDD test program. If an error is detected during the HDD test, an error code and status will be displayed. Replace the HDD with a new one following the instructions in Chapter 4, Replacement Procedures. The error codes and statuses are listed in Table 2-5. If an error code is not generated and the problem still exists, go to Procedure 5. Table 2-6 Hard disk drive error code and status Code 01h 02h 04h 05h 07h 08h 09h 0Ah 0Bh 10h 11h 20h 40h 80h AAh BBh CCh E0h EEh DAh Status Bad command Bad address mark Record not found HDC not reset Drive not initialized HDC overrun (DRQ) DMA boundary error Bad sector error Bad track error ECC error ECC recover enable HDC error Seek error Time out error Drive not ready Undefined error Write fault Status error Access time out error No HDD PORTEGE M100 Maintenance Manual (960-452) 2-35