Brother International HL-3400CN Service Manual - Page 100
PM-HP64M-BR
UPC - 012502526223
View all Brother International HL-3400CN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
HL-3400CN SERV10E MANUAL (6) DIMM block DIMM (Dual-Inline-Memory-Module) allows memory extension by up to 128MB in each socket. 2 DIMM sockets are available. The following type of DIMM can be installed into each slot. • Appearance: 100-pin • Memory type: SDRAM • Access time: PC66, CL2 • Parity: either Parity or Non-parity can be used • Memory capacity: 16MB, 32MB, 64MB, 128MB * 16MB: Techworks PM-HP16M-BR * 32MB: Techworks PM-HP32M-BR * 64MB: Techworks PM-HP64M-BR * 128MB: Techworks PM-HP128M-BR Any combination of DIMM size can be installed into any slot in any order. (7) External interface block • Centronics Interface • RS-232C Interface • PCMCIA Interface • MIO Interface • IDE Interface (8) Engine interface block The engine interface consists of the following signals; The signal indicating the engine is ready Signal requesting printing from the controller Signal indicating that a key switch status on the control panel has changed. Vertical synchronization signal for printing Horizontal synchronization signal for printing Video data signal Command signal sent from the controller to the engine Status signal sent from the engine to the controller