Fusing
UPC - 012502526223
View all Brother International HL-3400CN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 336 highlights
APPENDIX 6.3 Fusing Unit 1) Remove the fusing unit securing screws (2 pcs.) Screw 2) Holding the handles at both ends of the fusing unit and remove the fusing unit from the printer. 3) Remove the oil bottle and the fuser cleaner from the fusing unit and put each of them into the polyethylene bag. A CAUTION Pack the oil bottle in the polyethylene bag and seal it firmly. Failure to do so will cause oil spill during shipping and damage to the printer. 4) Put the oil bottle and the fuser cleaner into the original starter kit packing (L). ---ir---,---, Fig. A- 13 Screw i O , Fusing unit // Fig. A- 14 Oil bottle Fuser cleaner / Starter kit/ packing (L) K/ Fig. A- 15 5) Remove the oil remaining in the fusing unit with the supplied syringe to avoid oil spill in the printer. NOTE: Re-install the fusing unit into the printer after cleaning the printer as instructed in the following section. For re-installation of the fusing unit, see Section 6.6 `Packing'. Iv Fig. A- 16 A-16