Brother International HL-3400CN Service Manual - Page 39
Install, Bottle, Fuser, Cleaner
UPC - 012502526223
View all Brother International HL-3400CN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
CHAPTER 3iNSTALLATION (3) Remove the protective cover from the toner cartridge. (4) Install the four toner cartridges by sliding them gently along the guides into the printer. DO NOT USE FORCE TO INSERT THE CARTRIDGES AND DO NOT PUSH THEM FULLY INTO THE PRINTER, THEY WILL BE POSITIONED CORRECTLY WHEN THE FRONT COVER IS CLOSED. NOTE: The installation order of the four toner cartridges should be from the bottom to the top, in terms of colors this is in the order Cyan (C), Magenta (M), Yellow (Y), and Black (K). (3) Close the front cover. ~`~ Protective cover 0 Fig. 3-9 la ti Fig. 3-10 n n ' , _ :- " , . i._, ':,n-°7I-1--I-KM '.-`-- - oggF' I c LJ Fig. 3-11 3.3 Install the Oil Bottle and Fuser Cleaner (1) Release the two sets of retainer lock levers for both the oil bottle and the fuser cleaner. Pressure release (2) Set the fusing unit pressure release lever levers to the SET position. O Fig. 3-12 ec Pressure release lever 3-10