Brother International HL-3400CN Service Manual - Page 259
approximately
UPC - 012502526223
View all Brother International HL-3400CN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 259 highlights
CHAPTER 7 DISASSEMBL Y & RE-ASSEMBLY PR2000046 4.7.3 Fusing heater lamp ( using heater 3 (US)(EC ) (1) Remove the fixing screw ST3x6 (2 pcs.) and slide the F cover (B) to the right to remove it. (2) Remove the fixing screws with washer M3x6 (2 pc.) from securing the two heater harnesses. (1st and 3rd harnesses from the left hand side.) (3) Remove the fixing screws ST3x6 (4 pcs.) to remove the heater support (HR/BR) at the right hand side. (4) Remove the screw with washer M3x6 from the heater electrode plate of each lamp. (5) Pull out the fusing heater lamps from the inside of the back-up roller and fuser roller. Terminal (L) Heater support (BR) er- Fusing heater lamp J Heater support (HR) F cover (B) Heater harness Heater electrode plate Fig. 7-83 APRECAUTION • Do not touch the surface of the heater lamp with your hands, the small traces of oil you leave on the lamp will affect the life of the lamp. • The wattage of the heater lamp is different between the fuser roller and the back-up roller. The wattage is marked on the insulator of the lamp electrode. Fuser roller: 560W Back-up roller : 420W NOTE: When installing the new fusing unit into the printer, you have to wait approximately for 30 minutes after the unit is installed to allow the fusing oil to circulate in the unit. 7-54