developing AC bias is applied to the developing cylinder by the DEVELOPING AC BIAS
View all Canon LBP 2460 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
CHAPTER 2 the circuit applies a high voltage output bias. The high voltage output bias is applied only at the trailing edge of a single side print and during the second side of a duplex print. e. Toner sensing/cartridge sensing The EP-W cartridge has a toner sensor. The DC controller detects the toner level and whether a cartridge is installed when the developing AC bias is applied to the developing cylinder by the DEVELOPING AC BIAS DRIVE signal by checking the TONER LEVEL signal (TONRS) voltage. 2 - 20
the circuit applies a high voltage output bias.
The high voltage output bias is applied only at the
trailing edge of a single side print and during the second side of a duplex print.
e.
Toner sensing/cartridge sensing
The EP-W cartridge has a toner sensor.
The DC controller detects the toner level and whether a cartridge is installed when the
developing AC bias is applied to the developing cylinder by the DEVELOPING AC BIAS
DRIVE signal by checking the TONER LEVEL signal (TONRS) voltage.