Table 1-6. LCD Status Messages (continued) Code Text Causes Corrective Actions E141F CPU Protocol The system BIOS has reported a processor protocol error. See "Getting Help" on page 175. E1421 CPU Init The system BIOS has reported a processor initialization error. See "Getting Help" on page 175. E1422 CPU Machine Chk The system BIOS has reported a machine check error. See "Getting Help" on page 175. E1610 PS # Missing No power is available from the specified power supply; specified power supply is improperly installed or faulty. See "Troubleshooting Power Supplies" on page 147. E1614 PS # Status No power is available from the specified power supply; specified power supply is improperly installed or faulty. See "Troubleshooting Power Supplies" on page 147. E1618 PS # Predictive Power supply voltage is out of acceptable range; specified power supply is improperly installed or faulty. See "Troubleshooting Power Supplies" on page 147. E161C PS # Input Lost Power source for specified Check the AC power power supply is unavailable, source for the specified or out of acceptable range. power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 147. E1620 PS # Input Range Power source for specified Check the AC power power supply is unavailable, source for the specified or out of acceptable range. power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 147. About Your System 27