Dell PowerEdge R805 Hardware Owner's Manual (PDF) - Page 40
PCIe Degraded, Link Width Error, Embedded, Expected Link, Width is, Actual Link Width, Integrated
View all Dell PowerEdge R805 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Table 1-7. System Messages (continued) Message Causes Corrective Actions PCIe Degraded Faulty system board or riser See "Getting Help" on Link Width Error: board. page 175. Embedded device Expected Link Width is n Actual Link Width is n PCIe Degraded The specified PCIe device is For a SAS controller Link Width Error: faulty or improperly installed. daughter card, reseat the card Integrated in the dedicated PCIe device connector. See "Installing a Expected Link Width is n SAS Controller Daughter Card" on page 84. If the problem persists, see Actual Link Width is n "Getting Help" on page 175. PCIe Degraded Faulty or improperly installed Reseat the PCIe card in the Link Width Error: PCIe card in the specified specified slot number. See Slot n slot. "Expansion Cards" on Expected Link Width is n Actual Link Width page 91. If the problem persists, see "Getting Help" on page 175. is n PCIe Training Error: Embedded device Faulty system board or riser See "Getting Help" on board. page 175. PCIe Training Error: Integrated device The specified PCIe device is For a SAS controller faulty or improperly installed. daughter card, reseat the card in the dedicated PCIe connector. See "Installing a SAS Controller Daughter Card" on page 84. If the problem persists, see "Getting Help" on page 175. 40 About Your System