Dell PowerEdge R805 Hardware Owner's Manual (PDF) - Page 28
PS Redundancy, PS AC Current, E1710 I/O Channel, PCI PERR Slot - bios 1 0 2
View all Dell PowerEdge R805 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 1-6. LCD Status Messages (continued) Code Text Causes Corrective Actions E1624 PS Redundancy The power supply subsystem See "Troubleshooting is no longer redundant. If Power Supplies" on the last supply fails, the page 147. system will go down. E1625 PS AC Current Power source is out of acceptable range. Check the AC power source. E1710 I/O Channel Chk The system BIOS has reported an I/O channel check. See "Getting Help" on page 175. E1711 PCI PERR B## D## F## The system BIOS has Remove and reseat the reported a PCI parity error PCIe expansion cards. If on a component that resides the problem persists, see in PCI configuration space "Troubleshooting at bus ##, device ##, Expansion Cards" on function ##. page 158. PCI PERR Slot # The system BIOS has Reinstall the expansion- reported a PCI parity error card riser. See "Expansion- on a component that resides Card Risers" on page 99. in the specified PCIe slot. If the problem persists, the riser card or system board is faulty. See "Getting Help" on page 175. 28 About Your System