Plug & Play, Installing a RAC Card
View all Dell PowerEdge R805 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 41 highlights
Table 1-7. System Messages (continued) Message Causes Corrective Actions PCIe Training Error: Slot n Faulty or improperly installed Reseat the PCIe card in the PCIe card in the specified specified slot number. See slot. "Expansion Cards" on page 91. If the problem persists, see "Getting Help" on page 175. Plug & Play Configuration Error Error encountered in initializing PCIe device; faulty system board. Install the NVRAM_CLR jumper and reboot the system. See Figure 6-1 for jumper location. If the problem persists, see "Troubleshooting Expansion Cards" on page 158. Read fault Requested sector not found The operating system cannot Replace the USB medium or read from the hard drive or device. Ensure that the USB USB device, the system could or hard drive cables are not find a particular sector on properly connected. See the disk, or the requested "Troubleshooting a USB sector is defective. Device" on page 143, or "Troubleshooting a Hard Drive" on page 155 for the appropriate drive(s) installed in your system. Remote Access RAC cables not connected, Controller cable or RAC card installed in error or wrong expansion slot. incorrect card in the RAC slot. Check that the RAC cables are connected, and that the RAC card is installed in the correct expansion slot. See "Installing a RAC Card" on page 106. Remote configuration update attempt failed System unable to process Remote Configuration request Retry Remote Configuration. About Your System 41