MSB Control, Printable Code Area Expansion, MSB Control Sequence Cancel, MSB = 0 Setting
View all Epson FX-286 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 157 highlights
ESC I Printable Code Area Expansion Format: ASCII code: ESC Decimal: 27 Hexadecimal: 1 B I (n) 73 (n) 49 (n) Comments: ASCII codes 0 to 31 and 128 to 159 are usually not printable. These codes become printable upon input of the ESC I code if n = 1, which allows the use of these codes for user-defined characters. If n = 0, 0 to 31 and 128 to 159 return to non-printable codes. l Epson only. MSB Control Note: MSB control does not work for graphics data. ESC # MSB Control Sequence Cancel Format: ASCII code: ESC # Decimal : 27 35 Hexadecimal : 1B 23 Comments: Cancels the MSB control set by ESC = or ESC >. l Epson only. Note: MSB control does not work for graphics data. ESC = (equal) MSB = 0 Setting Format: ASCII code: ESC Decimal: 27 61 Hexadecimal: 1 B 3D Comments: Selects MSB as 0. When this code is input, the MSB of an eight-bit data input after this code becomes 0. l Epson only. G-29