HP ET115AV HP xw4400 Workstation - Service and Technical Reference Guide - Page 138
Run Computer Setup or Windows utilities., Connector from Power Supply
![]() |
View all HP ET115AV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 138 highlights
Table 5-18 POST error messages (continued) Screen message Probable cause Recommended action 917-Front Audio Not Connected The front audio cable is not connected. Connect front audio cable. 918-Front USB Not Connected Front USB is not connected. Connect front USB cable. 919-MultiBay Riser Not Connected MultiBay riser is not connected. Connect MultiBay riser. 920-Fan Command 2 Pin The 2-pin fan connector from the Connector from Power Supply power supply is not connected. Not Connected Connect 2-pin fan connector. 940-Extended ROM signature not found The signature at the start of the ROM Run SoftPaq again. flash is missing. Your firmware (BIOS) is incomplete. 960-CPU Overtemp occurred The ambient temperature could 1. Be sure you are not operating the system in an exceed operating limits environment that exceeds 95?F. (maximum=95?F), or there are obstructions to airflow, including dust 2. Disconnect power and open the access panel. build up. 3. Verify that cables are not blocking CPU heatsink fans or front fan, if installed. 4. Verify that there is not excessive dust on major components. 5. If airflow is acceptable and there is not excessive dust, the thermal sensing circuitry has failed on the processors or on the system board. You must replace the processors and/or the system board. 1151-Serial Port 1 Address Conflict Detected Both external and internal serial ports 1. Remove any Comm port expansion cards. are assigned to COM1. 2. Clear CMOS. 3. Reconfigure card resources and run Computer Setup (F10 Setup). 4. Run Computer Setup or Windows utilities. 1152-Serial Port 2 Address Conflict Detected Both external and internal serial ports 1. Remove any Comm port expansion cards. are assigned to COM2. 2. Clear CMOS. 3. Reconfigure card resources and run Computer Setup (F10 Setup). 4. Run Computer Setup or Windows utilities. 1155-Serial Port Address Conflict Detected Both external and internal serial ports 1. Remove any Comm port expansion cards. are assigned to same IRQ. 2. Clear CMOS. 3. Reconfigure card resources and run Computer Setup (F10 Setup). 4. Run Computer Setup or Windows utilities. 1201-System Audio Address Device IRQ address conflicts with Conflict Detected another device. Reset the IRQ. 1202-MIDI Port Address Conflict Detected Device IRQ address conflicts with another device. Reset the IRQ. 1203-Game Port Address Conflict Detected Device IRQ address conflicts with another device. Reset the IRQ 128 Chapter 5 System diagnostics and troubleshooting ENWW
![](/manual_guide/products/hewlettpackard-xw4400-hp-xw4400-workstation-service-technical-reference-guide-1bc38d3/138.png)