HP ET115AV HP xw4400 Workstation - Service and Technical Reference Guide - Page 139
Run Computer Setup F10 Setup., Disk Controller Failure
![]() |
View all HP ET115AV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
Table 5-18 POST error messages (continued) Screen message Probable cause Recommended action 1720 SMART Hard Drive Detect Imminent Failure Hard drive is about to fail. (Some hard 1. drives have a firmware patch that will fix an erroneous error message.) 2. Determine if hard drive is giving correct error message. Run the Drive Protection System test if applicable. 3. Apply firmware patch if applicable (see http://www.hp.com/support). 4. Back up contents and replace hard drive. 1780-Disk 0 Failure The drive is not installed correctly or has failed. 1. Be sure that any jumpers are set correctly, and that power and drive cables are connected, both to the drive and the system board. 2. Verify that the cables are the correct cables for your computer model. If this message persists, you might need service for your workstation. 1781-Disk 1 Failure The drive is not installed correctly or has failed. 1. Be sure that any jumpers are set correctly and that power and drive cables are connected, both to the drive and the system board. 2. Verify that the cables are the correct cables for your computer model. If this message persists, you may need service for your workstation. 1782-Disk Controller Failure Hard drive circuitry error. 1. Run Computer Setup (F10 Setup). 2. Clear CMOS. 3. Verify cable seating/jumper settings. 4. Run hard drive diagnostics. 5. Disconnect additional drives. 6. Run the Drive Protection System test if available. 7. Replace the hard drive. 8. Replace the system board. 1785-Multibay incorrectly installed No other IDE device may be attached Attach the MultiBay as device 0 on the secondary IDE to the same IDE controller. controller. 1790-Disk 0 Error The drive is not installed correctly or has failed. 1. Be sure that any jumpers are set correctly and that power and drive cables are connected, both to the drive and the system board. 2. Verify that the cables are the correct cables for your computer model. If this message persists, you may need service for your workstation. 1791-Disk 1 Error The drive is not installed correctly or has failed. 1. Be sure that any jumpers are set correctly and that power and drive cables are connected, both to the drive and the system board. 2. Verify that the cables are the correct cables for your computer model. If this message persists, you may need service for your workstation 1792-Secondary Disk Controller Failure Hard drive circuitry error. 1. Run Computer Setup (F10 Setup). 2. Clear CMOS. 3. Verify cable seating/jumper settings. 4. Run hard drive diagnostics. ENWW POST and error messages 129
![](/manual_guide/products/hewlettpackard-xw4400-hp-xw4400-workstation-service-technical-reference-guide-1bc38d3/139.png)