HP Workstation i2000 hp workstation i2000 owner's guide (a6037-90003) - Page 128

Power Supply Output Voltages

Page 128 highlights

Parameter Vin (115 VAC) Vin (230 VAC) Vin Frequency Iin (115 VAC) Iin (230 VAC) hp workstation i2000 owner's guide Table 27. AC Input Line Requirements Min Nom Max 90 115 135 180 230 265 47 -- 63 11.5 5.8 Unit VACrms VACrms Hz Arms Arms 12.2 Power Supply Output Voltages The DC output voltages shall remain within the regulation ranges shown in Table 28 when measured at the load end of the reference cable harness assemblies' connectors under all line, load, and environmental conditions. Table 28. DC Output Voltage Regulation Parameter Range1 Min. +12IO VDC2 + 5 VDC +3.3VDC -12 VDC +12DIG VDC3 +12CPU VDC3 +12CPU2 VDC3 + 3.3 VAUX + 5 VSB ± 5 % ± 4 % ± 4 % ± 10 % ± 5 % ± 5 % ± 5 % ± 5 % ± 5 % +11.40 +4.80 +3.17 -10.80 +11.40 +11.40 +11.40 +3.14 +4.75 1. Regulation at load end of reference cable harnesses 2. At +12V surge, regulation can go to ±10%. 3. This output provides power to DCDC converters Nom. +12.00 +5.00 +3.30 -12.00 +12.00 +12.00 +12.00 +3.30 +5.00 Max. +12.60 +5.20 +3.43 -13.20 +12.60 +12.60 +12.60 +3.47 +5.25 Unit Volts Volts Volts Volts Volts Volts Volts Volts Volts 128

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132

hp workstation i2000 owner’s guide
128
Table 27. AC Input Line Requirements
Parameter
Min
Nom
Max
Unit
V
in
(115 VAC)
90
115
135
VAC
rms
V
in
(230 VAC)
180
230
265
VAC
rms
V
in
Frequency
47
--
63
Hz
I
in
(115 VAC)
11.5
A
rms
I
in
(230 VAC)
5.8
A
rms
12.2
Power Supply Output Voltages
The DC output voltages shall remain within the regulation ranges shown in Table 28
when measured at the load end of the reference cable harness assemblies’ connectors
under all line, load, and environmental conditions.
Table 28. DC Output Voltage Regulation
Parameter
Range
1
Min.
Nom.
Max.
Unit
+12
IO
VDC
2
± 5 %
+11.40
+12.00
+12.60
Volts
+ 5 VDC
± 4 %
+4.80
+5.00
+5.20
Volts
+3.3VDC
± 4 %
+3.17
+3.30
+3.43
Volts
-12 VDC
± 10 %
-10.80
-12.00
-13.20
Volts
+12
DIG
VDC
3
± 5 %
+11.40
+12.00
+12.60
Volts
+12
CPU
VDC
3
± 5 %
+11.40
+12.00
+12.60
Volts
+12
CPU2
VDC
3
± 5 %
+11.40
+12.00
+12.60
Volts
+ 3.3 V
AUX
± 5 %
+3.14
+3.30
+3.47
Volts
+ 5 V
SB
± 5 %
+4.75
+5.00
+5.25
Volts
1.
Regulation at load end of reference cable harnesses
2.
At +12V surge, regulation can go to
±
10%.
3.
This output provides power to DCDC converters