IBM 4500R Hardware Maintenance Manual - Page 136
SCSI error codes, Temperature error messages, DASD bank 2 Over Temperature
UPC - 087944567837
View all IBM 4500R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 136 highlights
Error Code/Symptom FRU/Action I9990305 (Fixed boot 1. Install operating system to hard disk drive. sector error, no operating system installed) I9990650 (AC power 1. Check cable has been restored) 2. Check for interruption of power supply 3. Power Cable SCSI error codes Error Code FRU/Action All SCSI Errors One or 1. External SCSI devices must be powered-on before more of the following might be you power-on the server. causing the problem: 2. The cables for all external SCSI devices are • A failing SCSI device (adapter, connected correctly. drive, controller) 3. If you have attached an external SCSI device to the • An improper SCSI server, make sure the external SCSI termination is configuration or SCSI set to automatic. termination jumper setting 4. The last device in each SCSI chain is terminated • Duplicate SCSI IDs in the correctly. same SCSI chain 5. The SCSI devices are configured correctly. • A missing or improperly installed SCSI terminator • A defective SCSI terminator • An improperly installed cable • A defective cable Temperature error messages Message Action DASD bank 2 Over Temperature 1. Ensure system is being properly cooled; see (level-critical; Direct Access "Temperature checkout" on page 27. Storage Device bay "X" was over temperature) DASD Over recommened Temperature (sensor X) (level-warning; DASD bay "X" had over temperature condition) 1. Ensure system is being properly cooled; see "Temperature checkout" on page 27 . DASD under recommended 1. Ambient temperature must be within normal temperature (sensor X) (level- operating specifications; see "Features and warning; direct access storage specifications" on page 3. device bay "X" had under temperature condition) 128 Hardware Maintenance Manual: Netfinity 4500R Type 8656