IBM 4500R Hardware Maintenance Manual - Page 31
NDIS 4.0 (Windows NT) driver messages, PCI Slot/Device Information
UPC - 087944567837
View all IBM 4500R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Table 3. NDIS 2.01 (OS/2) driver messages for the Ethernet controller. PCNTND-21 The adapter failed the checksum test. Explanation: The driver cannot find an Ethernet controller. Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, go to "Starting the diagnostic programs" on page 14 to run the diagnostic programs. PCNTND-23 WARNING: PCNET IRQ found = xx Explanation: The interrupt request (IRQ) setting (xx) in the PROTOCOL.INI file does not match the hardware IRQ setting. Action: Remove the IRQ setting from the PROTOCOL.INI file or change the IRQ setting in the PROTOCOL.INI file to match the IRQ setting shown in the PCI Slot/Device Information selection of the Advanced Setup menu in the Configuration/Setup Utility program. PCNTND-24 WARNING: PCNET IRQ does not match PROTOCOL.INI. Explanation: The interrupt request (IRQ) setting in the PROTOCOL.INI file does not match the hardware IRQ setting. Action: Remove the IRQ setting from the PROTOCOL.INI file or change the IRQ setting in the PROTOCOL.INI file to match the IRQ setting shown in the PCI Slot/Device Information selection of the Advanced Setup menu in the Configuration/Setup Utility program. PCNTND-25 PCI scan specified, PCI bus not found! Explanation: The driver cannot locate the PCI bus. the diagnostic programs. PCNTND-29 WARNING: DMA number is not necessary for PCI device. Action: Run Explanation: The Ethernet controller does not require a DMA setting. Remove the DMA setting in the PROTOCOL.INI file. PCNTND-33 PCNET device with specified IOBASE is already in use. Action: Explanation: The specified I/O address number is already in use by another Ethernet controller or device. Action: Remove the I/O address setting in the PROTOCOL.INI file. NDIS 4.0 (Windows NT) driver messages This section contains the error messages for the NDIS 4.0 drivers. The explanation and recommended action are included with each message. Table 4. NDIS (Windows NT) driver messages for the Ethernet controller. PermaNet™Server: No Secondary Adapter Found. Grouping Mode is disabled. PermaNet Server: Explanation: The failover option requires an adapter that is compatible with the device driver of the Ethernet controller on the system board. No such adapter was found. Action: Make sure the correct adapter is installed. Problem Occurs on the Primary Adapter. Switching over to the Secondary Adapter. Explanation: The system detected a problem with the primary Ethernet connection and has transferred all network traffic to the secondary Ethernet controller. Action: Identify the cause of the failure on the primary Ethernet connection. Restoring the operational state of the primary connection will cause the network traffic to automatically transfer to the primary Ethernet controller. Diagnostics 23