IBM 4500R Hardware Maintenance Manual - Page 29
The Multiple Link Interface Driver MLID did not initialize MSMTx Free
UPC - 087944567837
View all IBM 4500R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Table 2. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller. PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not initialize MSMTx Free Count. Explanation: The MSMTx Free Count is not initialized correctly. Action: Restart the server. If the problem persists, go to "Starting the diagnostic programs" on page 14 to run the diagnostic programs. . PCNTNW-NW-086 The driver parameter block is too small. Explanation: The driver parameter block is too small. Action: Restart the server. If the problem persists, go to "Starting the diagnostic programs" on page 14 to run the diagnostic programs. PCNTNW-NW-087 The media parameter block is too small. Explanation: The driver media parameter block is too small. Action: Restart the server. If the problem persists, go to "Starting the diagnostic programs" on page 14 to run the diagnostic programs. PCNTNW-NW-091 The hardware configuration conflicts. Explanation: You tried to load a new frame type for the existing controller. The hardware assumptions made in doing so are incorrect. This error can also occur if you try to specify a mode (such as, redundancy) that conflicts with another specified mode. Action: Make sure that your hardware configuration matches the software settings. PCNTNW-NW-126 The group bit in the node address override was cleared. Explanation: The IEEE address has a group bit that indicates that an address belongs to a group of stations. This bit is used only as a destination address; it cannot be used as a source address. You tried to enter a source address with this bit set. The driver cleared the group bit of the source address. Action: None necessary, message is for information only. PCNTNW-NW-127 The local bit in the node address override was set. Explanation: The local bit in the IEEE address format indicates that the addresses are being managed locally. If you use the node address override capabilities of this driver to enter a new address, the local bit must be set. You entered an address without the local bit set. The driver has set the local bit. Action: None necessary, message is for information only. PCNTNW-NW-164 The device was not found. Explanation: The driver cannot find an Ethernet controller in the server. Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, go to "Starting the diagnostic programs" on page 14 to run the diagnostic programs. PCNTNW-NW-165 The device was not found at IOADDRESS. Explanation: The Ethernet controller cannot be found at the I/O address specified. Action: The Ethernet controller does not require a parameter for the I/O address. Remove the I/O address parameter. PCNTNW-NW-167 PCI scan specified, device not found. Explanation: The driver cannot locate the Ethernet controller on the PCI bus. Action: Verify that the Ethernet controller is enabled. If the problem persists, go to "Starting the diagnostic programs" on page 14 to run the diagnostic programs. Diagnostics 21