IBM 86624RY Maintenance Manual - Page 131
Controller DCh DSID NCh, Controller, Controller Channel SID, NState, Channel, for Ready
UPC - 087944490654
View all IBM 86624RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 131 highlights
GETSTATUS command to obtain progress information about the rebuild. Supported operating systems: Windows NT, OS/2, NetWare, OpenServer, UnixWare, and DOS Command: IPSSEND REBUILD Controller DCh DSID NCh NSID Replace: Controller with the ServeRAID controller number (1 to 8) DCh with the channel number for the Defunct drive (1 to 3) DSID with the SCSI ID for the Defunct Drive (0 to 15) NCh with the channel number for the New Drive (1 to 3) NSID with the SCSI ID for the New Drive (0 to 15) SETSTATE Use the SETSTATE command to change the state of a physical device from its current state to a new state. Attention You must be very careful when you use this command. For example, you might lose data if you reset a Defunct (DDD) device to Online (ONL) without first performing a Rebuild operation. Supported operating systems: Windows NT, OS/2, NetWare, OpenServer, UnixWare, and DOS Command: IPSSEND SETSTATE Controller Channel SID NState Replace: Controller with the ServeRAID controller number (1 to 8) Channel with the channel number for the drive (1 to 3) SID with the SCSI ID for the drive (0 to 15) NState with the new state for the drive. Valid states are: EMP for Empty, RDY for Ready, HSP for Hot Spare, SHS for Standby Hot Spare, DDD for Defunct Disk Drive, DHS for Defunct Hot Spare, RBL for Rebuild, SBY for Standby, and ONL for Online. (See "Setting physical Netfinity 5500 M20 - Type 8662 123