IBM 86624RY Maintenance Manual - Page 329
SCSI ID 5 is now located at Channel 1, SCSI ID 14., is the channel that matches the existing drive
![]() |
UPC - 087944490654
View all IBM 86624RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 329 highlights
Note When you install drives in a server that has no logical drives defined, the F7 choice will not appear. The ServeRAID adapter or controller does not contain any logical drives in its factory configuration. Therefore, F7 will not appear. In this case, do the following: 1. Restart the server and press Ctrl+I to enter the Mini-Configuration program. 2. Select Advanced Functions. 3. Select Import Configuration from Drives to Controller and follow the instructions on the screen. Controller is not responding to commands. No logical drives are installed. Explanation: The ServeRAID adapter or controller is not operational. Action: Reseat the controller. If problem persists, replace the ServeRAID controller. Error: Cannot disable this controller BIOS. Explanation: The ServeRAID adapter or controller was unable to prevent an extra copy of its BIOS code from being stored on the server. This condition occurs when the server contains multiple ServeRAID controllers or controllers. Action: This is an information message. No action is required. Following drives found in new location (old ch: old SID > new ch: new SID) Explanation: Configured drives are not in the configured location. This message will be preceded by the previous messages and the F5 key choice because configured drives were not found in the configured location. Appears when the ServeRAID adapter or controller detects that a previously configured drive is present, but the drive is in a new location. Where: old ch is the channel that matches the existing drive configuration information. old SID is the SCSI ID that matches the existing drive configuration information. new ch is the channel where the drive is now located. new SID is the SCSI ID where the drive is now located. For example: (1:5 > 1:14) In this example, the message indicates that the drive from Channel 1, SCSI ID 5 is now located at Channel 1, SCSI ID 14. The drive might have been physically moved to the new drive bay. Action: Press one of the following keys: F4 Retry. Press this key after correcting a problem. For example, press F4 after you move the hard disk drive to its previously assigned location. F5 Accept. Press this key to accept the new state that the ServeRAID adapter or controller will assign to the drive. For example, the ServeRAID adapter or controller will assign the drive a state of defunct (DDD) or empty (EMP). Netfinity 5500 M20 - Type 8662 321
![](/manual_guide/products/ibm-86624ry-maintenance-manual-8d18aa9/329.png)