IBM 86624RY Maintenance Manual - Page 323
Refer to the HMM Hardware Maintenance, BIOS/Firmware from the IBM Website.
UPC - 087944490654
View all IBM 86624RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 323 highlights
2. Flash the controller with the latest IBM ServeRAID BIOS/Firmware from the IBM Website. 3. Remove the jumpers. 4. If the error persists, replace ServeRAID controller. 9XXX thru BXXX (SCSI bus error caused either by defective drives, termination, etc.) 1. Isolate between SCSI subsystem and controller by disconnecting all SCSI cables from suspect card, and reboot. CAUTION: Do not press F5. Doing so changes the customer's configuration. If an ISPR error is still present, perform the following actions until the error is no longer present: a. Reseat the controller b. Replace the controller Note 1. Refer to the HMM (Hardware Maintenance Manual) specific to the system comprising the SCSI channel for SCSI cable details. 2. The controller detects a configuration change. Do not choose Save Changes. Instead, press F10 to bypass any options to this effect. 2. If ISPR error is EF10 after disconnecting cables: a. Identify which channel is causing the error by the second digit of the original ISPR code: ISPR = B1xx = Channel 1 ISPR = B2xx = Channel 2 ISPR = B3xx = Channel 1 and 2 ISPR = B4xx = Channel 3 ISPR = B5xx = Channel 1 and 3 ISPR = B6xx = Channel 2 and 3 ISPR = B7xx = Channel 1, 2 and 3 ISPR = BFxx = Channel not identified b. Confirm that the channel(s) identified from the error in step 2a is(are) the cause of the error by verifying that the error presents itself ONLY when the offending channel is reconnected. c. Check termination of identified channel. Note Refer to the HMM (Hardware Maintenance Manual) specific to the system comprising the SCSI channel for termination details. d. Check for proper backplane jumper configuration. Netfinity 5500 M20 - Type 8662 315