Lantronix SISPM1040-3166-L Web User Guide Rev G PDF 14.13 MB - Page 352
Loss Measurement Availability
View all Lantronix SISPM1040-3166-L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 352 highlights
Transition Networks SISPM1040-3xxx-L Web User Guide Loss Threshold : Far end loss threshold count is incremented if a loss measurement is above this threshold. SLM Test ID : The Test ID value to use in SLM PDUs (see G.8013, section 9.22.1). The default value is 0. Loss Measurement State Peer MEP : The Peer MEP ID that the following state relates to. Tx : The accumulated transmitted LM PDUs - since last 'clear'. Rx : The accumulated received LM PDUs - since last 'clear'. Near Loss : This field contains both the number of measurement intervals that has contributed to the near end frame loss and the total near end frame loss count - since last 'clear'. Far Loss : This field contains both the number of measurement intervals that has contributed to the far end frame loss and the total far end frame loss count - since last 'clear'. Thres.Count (near/far) : The number of times the near end and far end frame loss thresholds has been crossed. Near FLR (int/tot) : The interval and total near end frame loss ratio calculated based on the near end frame loss count and far end frame transmitted. The result is given in 100 * percent. Far FLR (int/tot) : The interval and total far end frame loss ratio calculated based on the far end frame loss count and near end frame transmitted. The result is given in 100 * percent. Near FLR (min/max) : The minimum and maximum non-zero near end frame loss ratio calculated based on the near end frame loss count and far end frame transmitted. The result is given in 100 * percent. A value of zero means that no loss has been encountered since last clear. Far FLR (min/max) : The minimum and maximum non-zero far end frame loss ratio calculated based on the far end frame loss count and near end frame transmitted. The result is given in 100 * percent. A value of zero means that no loss has been encountered since last clear. Intervals : The number of FLR expired intervals. Clear : Set of this check and save will clear the accumulated counters and restart ratio calculation. Loss Measurement Availability Enable : Enable/disable of loss measurement availability. Interval : Availability interval - number of measurements with same availability in order to change availability state. The valid range is 1 to 1000. FLR Threshold : Availability frame loss ratio threshold in per mille (per thousand). Maintenance : Enable/disable of loss measurement availability maintenance. 33763 Rev. G https://www.transition.com Page 352 of 496