Lantronix SISPM1040-3166-L Web User Guide Rev G PDF 14.13 MB - Page 80
Nothing, Reboot Remote PD
View all Lantronix SISPM1040-3166-L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 80 highlights
Transition Networks SISPM1040-3xxx-L Web User Guide 5-4 PoE Management > PoE Auto Checking This page lets you specify the Auto Power Reset parameters to check the link status between PoE ports and PDs. When a failed connection is detected, the switch will reboot remote the PD automatically. Ping Check : When on, the Ping Check function detects the connection between PoE port and power device. Setting to off will turn off the Ping Check function. Port : This is the logical port number for this row. Ping IP Address : The PD's IP Address the system should ping. Startup Time(sec) : When PD has been started up, the Switch will wait Start up time to do PoE Auto Power Reset. The default is 60 seconds; the valid range is 30-600 seconds. Interval Time(sec) : The switch will send checking message to PD each interval time. The default is 30 seconds; the valid range is 10-120 seconds. Retry Time : When a PoE port cannot ping the PD, it will try to send detection again. After the set number of retry attempts, a configurable failure action is triggered. The default is 3 retries; the valid range is 1-5 retry attempts. Failure Log : Failure loggings counter. Failure Action : The action when the third fail detection: Nothing: Keep Ping the remote PD but does nothing further. Reboot Remote PD: Cut off the power of the PoE port, make PD reboot. 33763 Rev. G https://www.transition.com Page 80 of 496