Mackie D8B Owners Manual - Page 129
HDR 24/96, ADAT Optical Hookup with OPT, Console Settings
View all Mackie D8B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
Console Settings 1. If you have DIO•8 cards installed, set the Tape Input and Tape Output format for each card to ADAT. OPT•8 cards need no configuration. 2. If the D8B is the clock master, set the Sample Rate to either 44.1kHz or 48kHz, and set the Apogee Clock to Internal (in the Digital I/O Setup window). If it is a clock slave, then set the Apogee Clock to Word Clock. Set the Sample Rate to match the Sample Rate selected on the HDR24/96. ADAT Optical Hookup with OPT•8 Apogee Clock I/O Card Word Clock Out APOGEE SYNC Word Clock Out APOGEE Word Clock In Word Clock In OPT•8 Cards ADAT Optical Out Digital•8 Bus ADAT Optical In Word Clock Out (HDR24/96 as Master) WARNING NOT Depress the Termination button if the HDR24/96 is set to Slave Word Clock Out (D8B as Master) HDR Sync Card Use one only Word Clock In Word Clock Out S C ADAT Optical Out HDR 24/96 ADAT Optical In OPT•8 Cards D8B Manual • Chapter 4 • page 123