Warning, Prepare a new image drum cartridge., Install a new toner cartridge in the image

Page 59 highlights

Memo • For information on how to return used image drum cartridges, see "Collection of Used Consumables" in the section of customer support / maintenance product warranty / product warranty. If you choose not to return your used image drum cartridges, place them in a plastic bag and dispose of them according to local regulations. Never put a used image drum or Warning toner cartridge into a fire. The toner inside could explode and cause burns. 4 Prepare a new image drum cartridge. Note • Do not tilt the image drum. The toner might spill. • The image drum (the green tube) is fragile; handle it carefully. • Do not expose the image drum cartridge to direct sunlight or strong light (more than about 1,500 lux). Do not expose them to room lighting for more than 5 minutes. (1) Place the image drum cartridge on top of a newspaper. (2) Peel off the tape that secures the protective sheet, and carefully remove it in the direction of arrow. Protective sheet Protective sheet Tape (3) Remove the desiccant (drying agent). Drying agent Replacing Consumables / Maintenance Units 5 Install a new toner cartridge in the image drum cartridge. Note 1 • Although it is possible to reinstall the toner cartridge that are currently in use, we recommend using a new toner cartridge for the following reasons. - Print quality may deteriorate, if more than a year has passed since the toner cartridge was opened. - New image drum cartridges are empty. Once you have installed a toner cartridge, the new 2 image drum will fill with toner from that toner cartridge. Therefore, if you install a toner cartridge that has only a little toner, the message [Toner Empty] may appear immediately. - If you reinstall a toner cartridge currently in use, the indicator which shows the amount of remaining toner will be inaccurate. (1) Remove the new toner cartridge from its packaging. 3 Note • Make sure that the color of the new toner cartridge is correct. (2) Gently shake it up and down and side to side several times. 4 Toner cartridge (3) Lay the toner cartridge flat, and gently 5 remove the tape. Tape 6 (4) Make sure that the label color of the toner cartridge matches the label color of the image drum cartridge. (5) Remove the toner cover from the image drum cartridge. Protuberance Toner cover 7 - 59 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79

Replacing Consumables / Maintenance Units
- 59 -
2
1
3
4
5
6
7
Memo
For information on how to return used image drum
cartridges, see "Collection of Used Consumables"
in the section of customer support / maintenance
product warranty / product warranty. If you choose
not to return your used image drum cartridges,
place them in a plastic bag and dispose of them
according to local regulations.
4
Prepare a new image drum cartridge.
Note
Do not tilt the image drum. The toner might spill.
The image drum (the green tube) is fragile; handle it
carefully.
Do not expose the image drum cartridge to direct
sunlight or strong light (more than about 1,500 lux). Do
not expose them to room lighting for more than 5
minutes.
(1)
Place the image drum cartridge on top of a
newspaper.
(2)
Peel off the tape that secures the
protective sheet, and carefully remove it in
the direction of arrow.
(3)
Remove the desiccant (drying agent).
5
Install a new toner cartridge in the image
drum cartridge.
Note
Although it is possible to reinstall the toner cartridge
that are currently in use, we recommend using a new
toner cartridge for the following reasons.
-
Print quality may deteriorate, if more than a year
has passed since the toner cartridge was
opened.
-
New image drum cartridges are empty. Once
you have installed a toner cartridge, the new
image drum will fill with toner from that toner
cartridge. Therefore, if you install a toner
cartridge that has only a little toner, the message
[Toner Empty] may appear immediately.
-
If you reinstall a toner cartridge currently in use,
the indicator which shows the amount of
remaining toner will be inaccurate.
(1)
Remove the new toner cartridge from its
packaging.
Note
Make sure that the color of the new toner cartridge is
correct.
(2)
Gently shake it up and down and side to
side several times.
(3)
Lay the toner cartridge flat, and gently
remove the tape.
(4)
Make sure that the label color of the toner
cartridge matches the label color of the
image drum cartridge.
(5)
Remove the toner cover from the image
drum cartridge.
Warning
Never put a used image drum or
toner cartridge into a fire. The
toner inside could explode and
cause burns.
Protective
sheet
Tape
Protective
sheet
Drying agent
Toner cartridge
Tape
Protuberance
Toner cover