3-44 Diagnostic Tools DAAD Diagnostic Messages Continued Message Description Recommended Action Logical Drive X status = WRONG DRIVE REPLACED A physical drive in this logical drive has failed. The incorrect drive was replaced. Replace the drive that was incorrectly replaced. Then, replace the original drive that failed with a new drive. Do not run the System Configuration Utility to reconfigure; you will lose data on the drive. Loose cable detected - logical drives may be marked FAILED until corrected Controller unable to communicate with one or more physical drives, probably because of a cabling problem. Logical drives may be in a FAILED state until the condition is corrected, preventing access to data on the controller. Check all controller and drive cable connections. Mirror data miscompare Data was found at reinitialization in the posted write memory; however, the mirror data compare test failed resulting in data being marked as invalid. Data loss is possible. Replace the array accelerator board. Mirrored memory location errors Soft errors occurred when attempting to read the same data from both sides of the mirrored memory. Data loss will occur. Replace the array accelerator board. No configuration for Accelerator Board The array accelerator board has not been configured. If the array accelerator board is present, run the System Configuration Utility to configure the board, if desired. SCSI port X, drive ID Y firmware needs upgrading Drive's firmware may cause problems and should be upgraded. Run Options ROMPaq to upgrade the drive's firmware to a later revision. Set configuration command issued The configuration of the array controller has been updated. The array accelerator board may remain disabled until it is reinitialized. Run the System Configuration Utility to reinitialize the array accelerator board. Soft Firmware Upgrade required DAAD has determined that your controller is running firmware that has been soft upgraded by the Compaq Upgrade Utility. However, the firmware running is not present on all drives. This could be caused by the addition of new drives in the system. Run the Compaq Upgrade Utility to place the latest firmware on all drives. Threshold for drive (bay) X violated This message indicates that a monitor and performance threshold for this drive has been violated. Check for the particular threshold that has been violated. Continued