Memory Test Error Codes, Table 3-3
View all HP ProLiant 3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
3-20 Diagnostic Tools Memory Test Error Codes The 200 series of Diagnostic error codes identifies failures with the memory subsystem. Error Code 200-xx 201-xx 202-xx 203-xx 204-xx 205-xx 206-xx 207-xx 208-xx 210-xx 215 Table 3-3 Memory Test Error Codes Description Invalid memory configuration. Memory machine ID test failed. Memory system ROM checksum failed. Recommended Action Reinsert memory modules in correct location and retest. The following steps apply to error codes 201-xx and 202-xx: 1. Replace the system ROM and retest. 2. Replace the processor board and retest. 3. Replace the memory expansion board and retest. Memory write/read test failed. Memory address test failed. Walking I/O test failed. Increment pattern test failed. The following steps apply to error codes 203-xx through 210-xx: 1. Replace the memory module and retest. 2. Replace the processor board and retest. 3. Replace the memory expansion board and retest. Invalid memory configuration-check DIMM installation. DIMMs installed have 8K refresh. Invalid memory speed detected - check DIMM installation. Slow DIMMs may cause data loss. Random pattern test failed. Non-functioning DC-DC converter for processor X. Replace DIMMs. Replace DIMMs with timing greater than 60 ns. 1. Replace the memory module and retest. 2. Replace the processor board and retest. 3. Replace the memory expansion board and retest. Replace the DC-DC converter(processor power module).