HP ProLiant 3000 ProLiant 3000 Servers Maintenance and Service Guide - Page 70

Operating in Interim, Select F1

Page 70 highlights

3-13 POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1787-Drive Array Operating in Interim Recovery Mode. Physical drive replacement needed: Drive X None Hard drive X failed or cable is loose or defective. Following a system restart, this message reminds you that drive X is defective and fault tolerance is being used. Recommended Action 1. Replace drive X as soon as possible. 2. Check loose cables. 3. Replace defective cables. *1788-Incorrect Drive Replaced: Drive X Drive(s) were incorrectly replaced: Drive Y Select "F1" to continue - drive array will remain disabled. Select "F2" to reset configuration - all data will be lost. None Drives are not installed in their Reinstall the drives correctly as original positions, so the drives indicated. have been disabled. See note below. Press F1 to restart the computer with the drive array disabled. -Or- Press F2 to use the drives as configured and lose all the data on them. *NOTE: The 1788 error message might also be displayed inadvertently due to a bad power cable connection to the drive or by noise on the data cable. If this message was due to a bad power cable connection, but not because of an incorrect drive replacement, repair the connection and press F2. -Or- If this message was not due to a bad power cable connection, and no drive replacement took place, this could indicate noise on the data cable. Check cable for proper routing. Continued Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162

3-13
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long
S=Short
Probable Source of Problem
Recommended Action
1787-Drive Array
Operating in Interim
Recovery Mode.
Physical drive
replacement needed:
Drive
X
None
Hard drive
X
failed or cable is
loose or defective. Following a
system restart, this message
reminds you that drive
X
is
defective and fault tolerance is
being used.
1.
Replace drive X as soon as
possible.
2.
Check loose cables.
3.
Replace defective cables.
*1788-Incorrect Drive
Replaced: Drive
X
Drive(s) were
incorrectly replaced:
Drive
Y
Select "F1" to
continue - drive array
will remain disabled.
Select "F2" to reset
configuration - all
data will be lost.
None
Drives are not installed in their
original positions, so the drives
have been disabled.
See
note
below.
Reinstall the drives correctly as
indicated.
Press
F1
to restart the computer with
the drive array disabled.
-Or-
Press
F2
to use the drives as
configured and lose all the data on
them.
*NOTE:
The 1788 error message might also be displayed inadvertently due to a bad power cable connection to the
drive or by noise on the data cable. If this message was due to a bad power cable connection, but not because of an
incorrect drive replacement, repair the connection and press
F2
.
-Or-
If this message was not due to a bad power cable connection, and no drive replacement took place, this could indicate
noise on the data cable. Check cable for proper routing.