HP ProLiant 3000 ProLiant 3000 Servers Maintenance and Service Guide - Page 83
Tape Drive Test Error Codes, Table 3-12
View all HP ProLiant 3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
3-26 Diagnostic Tools Tape Drive Test Error Codes The 1900 series of Diagnostic error codes identifies failures with tape cartridges, tape drives, tape drive cabling, adapter boards, or the system board assembly. Error Code 1900-xx 1901-xx 1902-xx 1903-xx 1904-xx 1905-xx 1906-xx Table 3-12 Tape Drive Test Error Codes Description Tape ID failed. Recommended Action 1. Replace the tape cartridge and retest. Tape servo write failed. Tape format failed. Tape drive sensor test failed. Tape BOT/EOT test failed. Tape read test failed. 2. Check and/or replace the signal cable and retest. 3. Check the switch settings on the adapter board (if applicable). 4. Replace the tape adapter board (if applicable) and retest. Tape write/read/compare test failed. 5. Replace the tape drive and retest. 6. Replace the system board and retest.