HP ProLiant 3000 ProLiant 3000 Servers Maintenance and Service Guide - Page 153
Drive bay X needs replacing DAAD Error, Automatic Server Recovery Reset Limit Reached
View all HP ProLiant 3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 153 highlights
error Continued Accelerator status Cache was automatically configured during last controller reset. This can occur when cacheboard is replaced with one of a different size., description 3-38 Data in the cache was lost due to some reason other than the battery being discharged, description 3-37 Dirty data detected has reached limit. Cache still enabled, but writes no longer being posted, description 3-37 Dirty data detected. Unable to write dirty data to drives, description 3-37 Excessive ECC errors detected in at least one cache line. As a result, at least on cache line is no longer in use, description 3-37 Obsolete data sensed at reset, description 3-37 Obsolete data was discarded, description 3-37 Obsolete data was written to drives, description 3-37 Permanently disabled, description 3-36 Possible data loss in cache, description 3-36 Temporarily disabled, description 3-36 Unrecognized status, description 3-36 Valid data found at reset, description 3-38 Warranty alert, description 3-38 Adapter/NVRAM ID mismatch, description 3-38 ASR-2 detected by ROM 3-60, 3-61 ASR-2 Test Event 3-60, 3-61 Automatic Server Recovery Base Memory Parity Error 3-60 Automatic Server Recovery Extended Memory Parity Error 3-60 Automatic Server Recovery Memory Parity Error 3-60 Automatic Server Recovery Reset Limit Reached 3-60 Battery Failing 3-60 Battery X not fully charged, description 3-38 beeps, description 3-16 Board not attached, description 3-38 Caution Temperature Exceeded 3-60, 3-61 Compatibility port problem detected, description 3-38 Index-7 error Continued Configuration signature is zero, description 3-39 Configuration signature mismatch, description 3-39 Controller communication failure occurred, description 3-39 Controller detected. NVRAM configuration not present, description 3-39 Controller firmware needs upgrading (DAAD Error 102), description 3-39 Controller firmware needs upgrading, description 3-39 Controller is located in special video slot, description 3-39 Controller is not configured, description 3-39 Controller needs replacing (DAAD Error 102), description 3-39 Controller needs replacing (DAAD Error 104), description 3-40 Controller reported POST error. Error Code x, description 3-40 Controller restarted with a signature of zero, description 3-40 DAAD recorded errors attempting to access X, description 3-40 Diagnostic Error 3-60 Disable command issued, description 3-40 Drive (bay) X firmware needs upgrading, description 3-41 Drive (bay) X has insufficient capacity for its configuration, description 3-41 Drive (bay) X has invalid M&P stamp, description 3-41 Drive (bay) X has loose cable, description 3-41 Drive (bay) X is a replacement drive marked OK, description 3-41 Drive (bay) X is a replacement drive, description 3-41 Drive (bay) X is failed, description 3-41 Drive (bay) X is undergoing drive recovery, description 3-41 Drive (bay) X needs replacing (DAAD Error 102), description 3-40 Drive (bay) X RIS copy mismatch, description 3-41 Drive (bay) X upload code not readable, description 3-41 Drive (bay) X was inadvertently replaced, description 3-42 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide