HP ProLiant 3000 ProLiant 3000 Servers Maintenance and Service Guide - Page 97
Restart the system. Run the System Configuration Utility, The Intelligent Array Expansion System
View all HP ProLiant 3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
3-40 Diagnostic Tools DAAD Diagnostic Messages Continued Message Description Controller needs replacing (DAAD Error 104) The Intelligent Array Expansion System firmware is less than version 1.14. Recommended Action Replace the controller as soon as possible. Controller reported POST error. The controller returned an error from its Replace the controller. internal Power-On Self Tests. Error Code: x Controller restarted with a signature of zero DAAD did not find a valid configuration signature to use to get the data. Nonvolatile RAM may not be present (unconfigured) or the signature present in nonvolatile RAM may not match the signature on the controller. Run the System Configuration Utility to configure the controller and nonvolatile RAM. DAAD recorded errors attempting to access: X DAAD found errors while attempting to access physical drive X, believed to be operational. Message followed by specific information about the error. Replace the drive, or correct the condition that caused the error. Disable command issued Posted-writes have been disabled by the issuing of the Accelerator Disable command. This occurred because of an operating system device driver. Restart the system. Run the System Configuration Utility to reinitialize the array accelerator board. Drive (bay) X needs replacing (DAAD Error 102) The 210-megabyte hard drive has firmware version 2.30 or 2.31. Replace the drive. Drive Monitoring features are unobtainable DAAD unable to get monitor and performance data due to fatal command problem such as drive timeout, or unable to get data due to these features not supported on the controller. Check for other errors (time-outs, and so on). If no other errors occur, upgrade the firmware to a version that supports monitor and performance, if desired. Drive Monitoring is NOT enabled for drive bay X The monitor and performance features have not been enabled. Run the System Configuration Utility to initialize the monitor and performance features. Drive time-out occurred on physical drive bay X DAAD issued a command to a physical drive and the command was never acknowledged. The drive or cable may be bad. Check the other error messages on the Diagnostics screen to determine resolution. Continued