HP ProLiant 3000 ProLiant 3000 Servers Maintenance and Service Guide - Page 71
Reports Valid Data
View all HP ProLiant 3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
3-14 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1789-Drive Not Responding, Physical Drive None Cable or hard drive failure. Check cables or replace physical drive X. Recommended Action 1. Check the cable connections. 2. Replace the cables. 3. Replace the drive. 4. If you do not want to replace the drives now, press F2. Select "F1" to continue - drive array will remain disabled. Select "F2" to fail drive(s) that are not responding - Interim Recovery Mode will be enabled if configured for fault tolerance. 1790-Disk 0 Configuration Error None Hard drive error or wrong drive Run the System Configuration Utility type. and Diagnostics and correct. 1791-Disk 1 Error None Hard drive error or wrong drive Run the System Configuration Utility type. and Diagnostics and correct. 1792-Drive Array None This indicates that while the No action necessary; no data has been Reports Valid Data system was in use, power was lost. Perform orderly system Found in Array interrupted while data was in shutdowns to avoid data remaining in Accelerator. the Array Accelerator memory. the Array Accelerator. Data will automatically be written to drive array. Power was then restored within eight to ten days, and the data in the Array Accelerator was flushed to the drive array. Continued